SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 13 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
The XOR password has to be calculated with the password and two times the received
random number from the last GET RANDOM NUMBER command:
XOR_Password[31:0] = Password[31:0] XOR {Random_Number[15:0],
Random_Number[15:0]}.
The different passwords are addressed with the password identifier.
Remark: If the IC receives an invalid password, it will not execute any following command
until a Power-On Reset (POR) (RF reset) is executed.
8.4.3.3 WRITE PASSWORD
Command code = B4h
The WRITE PASSWORD command enables a new password to be written into the related
memory if the related old password has already been transmitted with a SET PASSWORD
command and the addressed password is not locked (see Section 8.4.3.4 “
LOCK
PASSWORD).
Remark: The WRITE PASSWORD command can only be executed in addressed or
selected mode. The new password takes effect immediately which means that the new
password has to be transmitted with the SET PASSWORD command to access protected
blocks/pages.
The different passwords are addressed with the password identifier.
The timing of the command is write alike.
Option 0 (Option flag not set) is supported.
Table 9. Request format
SOF Flags SET
PASSWORD
IC Mfg
code
UID Password
identifier
XOR
password
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 32 bits 16 bits -
Table 10. Password Identifier
Password identifier Password
01h Read
02h Write
04h Privacy
08h Destroy SLIX-S
10h EAS/AFI
Table 11. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 12. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 14 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
Option 1 (Option flag set) is supported.
8.4.3.4 LOCK PASSWORD
Command code = B5h
The LOCK PASSWORD command enables the addressed password to be locked if the
related password has already been transmitted with a SET PASSWORD command. A
locked password cannot be changed.
The different passwords are addressed with the password identifier.
The timing of the command is write alike.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
Table 13. Request format
SOF Flags WRITE
PASSWORD
IC Mfg
code
UID Password
identifier
Password CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 32 bits 16 bits -
Table 14. Password Identifier
Password identifier Password
01h Read
02h Write
04h Privacy
08h Destroy SLIX-S
10h EAS/AFI
Table 15. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 16. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
Table 17. Request format
SOF Flags LOCK
PASSWORD
IC Mfg
code
UID Password
identifier
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 16 bits -
SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 15 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
8.4.3.5 64 BIT PASSWORD PROTECTION
Command code = BBh
The 64-bit PASSWORD PROTECTION command enables the Label IC to be instructed
that both of the Read and Write passwords are required to get access to password
protected blocks (pages). This mode can be enabled if the Read and Write passwords
have been transmitted first with a SET PASSWORD command.
If the 64-bit password protection is enabled, both passwords are required for read & write
access to protected blocks (pages).
Once the 64 bit password protection is enabled, a change back to 32-bit password
protection (read and write password) is not possible.
Remark: A retransmission of the passwords is not required after the execution of the
64-bit PASSWORD PROTECT EAS/AFI command.
The timing of the command is write alike.
Table 18. Password identifier
Password identifier Password
01h Read
02h Write
04h Privacy
08h Destroy SLIX-S
10h EAS/AFI
Table 19. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 20. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
Table 21. Request format
SOF Flags 64 BIT
PASSWORD
PROTECTION
IC Mfg code UID CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
16 bits -
Table 22. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 23. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -

SL2S5402FUD,003

Mfr. #:
Manufacturer:
NXP Semiconductors
Description:
RFID Transponders ICODE SLIX-S
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union