SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 16 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
8.4.3.6 PROTECT PAGE
Command code = B6h
The PROTECT PAGE command enables the page protection condition to be changed
under the following circumstances:
The related passwords (Read and/or Write password) have been transmitted first with
the SET PASSWORD command. If the 64-bit PASSWORD PROTECT EAS/AFI is
enabled, the Read and Write passwords have to be transmitted first.
The addressed page protection condition is not locked (see Section 8.4.3.7 “LOCK
PAGE PROTECTION CONDITION” on page 16
The timing of the command is write alike.
8.4.3.7 LOCK PAGE PROTECTION CONDITION
Command code = B7h
The LOCK PAGE PROTECTION CONDITION command enables the status of the page
protection condition of the related page to be locked if the Read and Write passwords
have been transmitted first with the SET PASSWORD command.
The timing of the command is write alike.
Table 24. Request format
SOF Flags PROTECT
PAGE
IC Mfg
code
UID Page
number
Protectio
n status
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 8 bits 16 bits -
Table 25. Protection status
Protection status 32 bit password protection 64 bit password protection
00h Public Public
01h Read and Write protected by the
Read password
Read and Write protected by the
Read plus Write password
10h Write protected by the Write
password
Write protected by the Read plus
Write password
11h Read protected by the Read
password and Write protected by the
Write password
Read and Write protected by the
Read plus Write password
Table 26. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 27. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 17 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
8.4.3.8 GET MULTIPLE BLOCK PROTECTION STATUS
Command code = B8h
The GET MULTIPLE BLOCK PROTECTION STATUS command requests the label to
respond with the block protection status of the requested blocks.
The number of blocks in the request is one less than the number of blocks that the ICODE
SLIX-S IC returns in its response.
Remark: If the sum of the first block number and the number of blocks exceeds the total
available number of user blocks, the number of transmitted security status bytes is less
than the requested number, which means that the last returned status byte is the one
corresponding to the highest available user block, followed by the 16-bit CRC and the
EOF.
Table 28. Request format
SOF Flags LOCK PAGE
PROTECTION
CONDITION
IC Mfg
code
UID Page
number
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 16 bits -
Table 29. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 30. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
Table 31. Request format
SOF Flags GET MULTIPLE
BLOCK
PROTECTION
STATUS
IC Mfg
code
UID First
block
number
Number
of
blocks
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 8 bits 16 bits -
Table 32. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 33. Response format when Error_flag NOT set
SOF Flags Block protection
status
CRC16 EOF
- 8 bits 8 bits 16 bits -
Repeated as needed
SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 18 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
[1] WAC: Write Access Condition.
8.4.3.9 DESTROY SLIX-S
Command code = B9h
The DESTROY SLIX-S command enables the ICODE SLIX-S Label IC to be destroyed if
the Destroy SLIX-S password is correct. This command is irreversible and the ICODE
SLIX-S will never respond to any command again.
The DESTROY SLIX-S command can only be executed in addressed or selected mode.
The XOR password has to be calculated with the password and two times the received
random number from the last GET RANDOM NUMBER command:
XOR_Password[31:0] = Password[31:0] XOR {Random_Number[15:0],
Random_Number[15:0]}.
The timing of the command is write alike.
Table 34. Block protection status
Bit Name Value Description
b1 (LSB) Lock bit (WAC)
[1]
0 Block is not locked
1 Block is locked (LOCK BLOCK command)
b2 Read password
protected
0 disabled
1 enabled
b3 Write password
protected
0 disabled
1 enabled
b4 Page protection
lock
0 not locked
1 locked
b5 to b8 (MSB) - 0
Table 35. Request format
SOF Flags DESTROY
SLIX-S
IC Mfg
code
UID XOR
password
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
32 bits 16 bits -
Table 36. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 37. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -

SL2S5402FUD,003

Mfr. #:
Manufacturer:
NXP Semiconductors
Description:
RFID Transponders ICODE SLIX-S
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet