SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 25 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
8.4.3.18 WRITE EAS ID
Command code = A7h
The command WRITE EAS ID enables a new EAS Identifier to be stored in the
corresponding configuration memory. If EAS is password protectd (for Set and Reset
EAS) the EAS password has to be first transmitted with the SET PASSWORD command.
The timing of the command is write alike.
8.5 Error handling
8.5.1 Transmission errors
According to ISO/IEC 15693 the label IC will not respond if a transmission error (CRC, bit
coding, bit count, wrong framing) is detected and will silently wait for the next correct
received command.
8.5.2 Not supported commands or options
If the received command or option is not supported, the behavior of the label IC depends
on the addressing mechanism.
8.5.2.1 Non Addressed Mode
The label IC remains silent.
8.5.2.2 Addressed or Selected Mode
The addressed or selected label IC responds with the error code “0Fh” (error with no
information given or error code is not supported).
If the Inventory flag or the Protocol Extension flag is set, the label IC will not respond if the
command or option is not supported.
Table 61. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
Table 62. Request format
SOF Flags WRITE
EAS ID
IC Mfg code UID EAS ID
value
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
16 bits 16 bits -
Table 63. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 64. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 26 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
8.5.3 Parameter out of range
8.5.3.1 Read commands
If the sum of the first block number and the number of blocks exceeds the total available
number of user blocks, the number of transmitted blocks is less than the requested
number of blocks, which means that the last returned block is the highest available user
block, followed by the 16-bit CRC and the EOF.
8.5.3.2 Write and lock commands
If the address of a block to be written does not exist or a block to be written is locked, the
behaviour of the label IC depends on the addressing mechanism.
Non Addressed Mode
The label IC remains silent and aborts the command without writing anything.
Addressed or Selected Mode
The addressed or selected label IC responds with the error code “0Fh” (error with no
information given or error code is not supported).
8.6 Data integrity
Following mechanisms are implemented in the contactless communication link between
interrogator and label to ensure very reliable data transmission:
16-bit CRC per block
Bit count checking
Bit coding to distinguish between logic 1, logic 0, and no information
Channel monitoring (protocol sequence and bit stream analysis)
8.7 RF interface
The definition of the RF interface is according to the standard ISO/IEC 15693-2 and
ISO/IEC 15693-3.
SL2S5302_SL2S5402 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.2 — 27 August 2012
192132 27 of 35
NXP Semiconductors
SL2S5302; SL2S5402
ICODE SLIX-S
9. Limiting values
[1] Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any conditions other than those described in the operating conditions and electrical
characteristics sections of this specification is not implied.
[2] This product includes circuitry specifically designed for the protection of its internal devices from the damaging effects of excessive static
charge. Nonetheless, it is suggested that conventional precautions be taken to avoid applying greater than the rated maxima.
[3] The voltage between LA and LB is limited by the on-chip voltage limitation circuitry (corresponding to parameter I
I
).
[4] For ESD measurement, the IC was mounted in a CDIP8 package.
10. Characteristics
10.1 Wafer memory characteristics
10.2 Interface characteristics
[1] Bandwidth limitation ( 7 kHz) according to ISM band regulations.
[2] Including losses in the resonant capacitor and rectifier.
[3] Measured with an HP4285A LCR meter at 13.56 MHz and 2 V RMS.
Table 65. Limiting values (Wafer)
[1][2]
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol Parameter Conditions Min Max Unit
T
stg
storage temperature 55 +125 C
P
tot
total power dissipation - 125 mW
T
j
junction temperature 40 +85 C
I
i(max)
maximum input current LA to LB; peak
[3]
- 60 mA
I
I
input current LA to LB; RMS - 30 mA
V
ESD
electrostatic discharge voltage Human body model
[4]
- 2kV
Table 66. Wafer EEPROM characteristics
Symbol Parameter Conditions Min Typ Max Unit
t
ret
retention time T
amb
 55 C50- - year
N
endu(W)
write endurance 100000 - - cycle
Table 67. Interface characteristics
Typical ratings are not guaranteed. The values listed are at room temperature.
Symbol Parameter Conditions Min Typ Max Unit
f
i
input frequency
[1]
13.553 13.56 13.567 MHz
V
i(RMS)min
minimum RMS input voltage operating
read/write
1.5 - 1.7 V
P
i(min)
minimum input power operating
[2]
-40-W
C
i
input capacitance between LA
and LB
[3]
SL5302FUD 22.3 23.5 24.7 pF
SL5402FUD 92 97 102 pF