10
0334G–FLASH–2/05
AT29LV040A
17. Software Protected Program Waveform
Notes: 1. OE must be high when WE and CE are both low.
2. A8 through A18 must specify the sector address during each high-to-low transition of WE (or CE) after the software code
has been entered.
3. All words that are not loaded within the sector being programmed will be indeterminate.
18. Programming Algorithm
(1)
16. Program Cycle Characteristics
Symbol Parameter Min Max Units
t
WC
Write Cycle Time 20 ms
t
AS
Address Set-up Time 10 ns
t
AH
Address Hold Time 100 ns
t
DS
Data Set-up Time 100 ns
t
DH
Data Hold Time 10 ns
t
WP
Write Pulse Width 200 ns
t
BLC
Byte Load Cycle Time 150 µs
t
WPH
Write Pulse Width High 200 ns
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA A0
TO
ADDRESS 5555
LOAD DATA
TO
SECTOR (256 BYTES)
(3)
WRITES ENABLED
ENTER DATA
PROTECT STATE
(2)
Notes: 1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Data Protect state will be re-activated at
end of program cycle.
3. 256 bytes of data MUST BE loaded.
11
0334G–FLASH–2/05
AT29LV040A
Notes: 1. These parameters are characterized and not 100% tested.
2. See t
OE
spec in AC Read Characteristics.
20. Data Polling Waveforms
Notes: 1. These parameters are characterized and not 100% tested.
2. See t
OE
spec in AC Read Characteristics.
22. Toggling Bit Waveforms
(1)(3)
Notes: 1. Toggling either OE or CE or both OE and CE will operate toggle bit.
2. Beginning and ending state of I/O6 will vary.
3. Any address location may be used by the address should not vary.
19. Data Polling Characteristics
(1)
Symbol Parameter Min Typ Max Units
t
DH
Data Hold Time 10 ns
t
OEH
OE Hold Time 10 ns
t
OE
OE to Output Delay
(2)
ns
t
WR
Write Recovery Time 0 ns
21. Toggle Bit Characteristics
(1)
Symbol Parameter Min Typ Max Units
t
DH
Data Hold Time 10 ns
t
OEH
OE Hold Time 10 ns
t
OE
OE to Output Delay
(2)
ns
t
OEHP
OE High Pulse 150 ns
t
WR
Write Recovery Time 0 ns
12
0334G–FLASH–2/05
AT29LV040A
23. Software Product Identification
Entry
(1)
24. Software Product Identification
Exit
(1)
Notes: 1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. A1 - A18 = V
IL
.
Manufacturer Code is read for A0 = V
IL
;
Device Code is read for A0 = V
IH
.
3. The device does not remain in identification mode if
powered down.
4. The device returns to standard operation mode.
5. Manufacturer Code is 1F. The Device Code is C4.
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 90
TO
ADDRESS 5555
PAUSE 20 mS ENTER PRODUCT
IDENTIFICATION
MODE
(2)(3)(5)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA F0
TO
ADDRESS 5555
PAUSE 20 mS EXIT PRODUCT
IDENTIFICATION
MODE
(4)
25. Boot Block Lockout
Feature Enable Algorithm
(1)
Notes: 1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Lockout feature set on lower address boot block.
3. Lockout feature set on higher address boot block.
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 80
TO
ADDRESS 5555
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 40
TO
ADDRESS 5555
LOAD DATA 00
TO
ADDRESS 00000H
(2)
PAUSE 20 mS
LOAD DATA FF
TO
ADDRESS FFFFFH
(3)
PAUSE 20 mS

AT29LV040A-15TC

Mfr. #:
Manufacturer:
Microchip Technology / Atmel
Description:
NOR Flash 4M (512kx8)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union