DC and AC parameters M95M01-R M95M01-W
28/41 Doc ID 13264 Rev 8
10 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Figure 15. AC measurement I/O waveform
Table 8. Operating conditions (M95M01-R6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 9. Operating conditions (M95M01-W3)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature –40 125 °C
Table 10. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
L
Load capacitance 100 pF
Input rise and fall times 50 ns
Input pulse voltages 0.2 V
CC
to 0.8 V
CC
V
Input and output timing reference voltages 0.3 V
CC
to 0.7 V
CC
V
Table 11. Capacitance
Symbol Parameter
(1)
1. Not 100% tested.
Test condition Min. Max. Unit
C
OUT
Output capacitance (Q) V
OUT
= 0 V 8 pF
C
IN
Input capacitance (D) V
IN
= 0 V 8 pF
Input capacitance (other pins) V
IN
= 0 V 6 pF
!)#
6
##
6
##
6
##
6
##
)NPUTANDOUTPUT
TIMINGREFERENCELEVELS
)NPUTVOLTAGELEVELS