ICS1894-33
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE PHYCEIVER
IDT®
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE 31
ICS1894-33 REV A 021612
DC Operating Characteristics for REFIN
The table below lists the 3.3V DC characteristics for the REFIN pin.
DC Operating Characteristics for RMII Interface Pins
The table below lists DC operating characteristics for the Reduced Media Independent Interface (RMII) for the
ICS1894-33.
Timing Diagrams
Timing for Clock Reference (REFIN) Pin
The table below lists the significant time periods for signals on the clock reference (REFIN) pin. The REFIN Timing
Diagram figure shows the timing diagram for the time periods.
REFIN Timing Diagram
Parameter Symbol Min. Max. Units
Input High Voltage V
IH
2.97 V
Input Low Voltage V
IL
–0.33 V
Parameter Conditions Min. Typ. Max. Units
RMII Input Pin Capacitance 8 pF
RMII Output Pin Capacitance 14 pF
RMII Output Drive Impedance VDDIO = 3.3V 20 Ω
Time
Period
Parameter Conditions Min. Typ. Max. Units
t1 REFIN Duty Cycle (RMII) 45 50 55 %
t2 REFIN Period (RMII) 20 ns
ICS1894-33
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE PHYCEIVER
IDT®
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE 32
ICS1894-33 REV A 021612
MII Management Interface Timing
The table below lists the significant time periods for the MII Management Interface timing (which consists of timings
of signals on the MDC and MDIO pins). The MII Management Interface Timing Diagram figure shows the timing
diagram for the time periods.
MII Management Interface Timing Diagram
Time
Period
Parameter Conditions Min. Typ. Max. Units
t1 MDC Minimum High Time 160 ns
t2 MDC Minimum Low Time 160 ns
t3 MDC Period 400 ns
t4 MDC Rise Time to MDIO Valid 0 300 ns
t5 MDIO Setup Time to MDC 10 ns
t6 MDIO Hold Time after MDC 10 ns
ICS1894-33
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE PHYCEIVER
IDT®
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE 33
ICS1894-33 REV A 021612
10Base-T: Normal Link Pulse Timing
The table below lists the significant time periods for the 10Base-T Normal Link Pulse (which consists of timings of
signals on the TP_TXP pins). The 10Base-T Normal Link Pulse Timing Diagram shows the timing diagram for the
time periods.
10Base-T Normal Link Pulse Timing Diagram
Time
Period
Parameter Conditions Min. Typ. Max. Units
t1 Normal Link Pulse Width 10Base-T 100 ns
t2 Normal Link Pulse to Normal Link Pulse Period 10Base-T 8 20 25 ms