Electrical specifications VNQ5027AK-E
16/31 Doc ID 12730 Rev 7
4 -6 V -7 V 1 pulse 100 ms, 0.01
Ω
5b
(2)
+65 V +87 V 1 pulse 400 ms, 2
Ω
Table 13. Electrical transient requirements (part 2/3)
ISO 7637-2:
2004(E)
test pulse
Test level results
(1)
III IV
1C C
2a C C
3a C C
3b C C
4C C
5b
(2)
CC
1. The above test levels must be considered referred to V
CC
= 13.5V except for pulse 5b.
2. Valid in case of external load dump clamp: 40V maximum referred to ground.
Table 14. Electrical transient requirements (part 3/3)
Class Contents
C All functions of the device are performed as designed after exposure to disturbance.
E
One or more functions of the device are not performed as designed after exposure
to disturbance and cannot be returned to proper operation without replacing the
device.
Table 12. Electrical transient requirements (part 1/3) (continued)
ISO 7637-2:
2004(E)
test pulse
Test levels
Number of
pulses or
test times
Burst cycle/pulse
repetition time
Delays and
Impedance
III IV