MAX6917
I
2
C-Compatible RTC with Microprocessor
Supervisor, Alarm, and NV RAM Controller
4 _______________________________________________________________________________________
DC ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= V
CC(MIN)
to V
CC(MAX)
, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at T
A
= +25°C.) (Notes 1, 2)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX
UNITS
CE_OUT Active-Low Delay After
V
CC
> V
RST
t
RP
140 200
280 ms
CE_OUT High Voltage V
OH
I
OH
= -100µA, V
BATT
= 2V, V
CC
= 0,
RESET = low
0.8 x
V
BATT
V
MR INPUT (Figure 10)
V
IL
0.8
MR Input Voltage
V
IH
2.0
V
MR Pullup Resistance Internal pullup resistor 50 k
MR Minimum Pulse Width s
MR Glitch Immunity t
GW
35 ns
MR to RESET Delay t
RD
V
CC
= V
CC(MIN)
, V
BATT
= 0
450
600 ns
WDI INPUT (Figure 12)
WDI Initial Timeout Period V
CC
> V
RST
from rising edge of RESET
1.00
1.6
2.25
s
t
WDL
Long watchdog timeout period
1.00
1.6
2.25
s
Watchdog Timeout Period
t
WDS
Short watchdog timeout period
140 200
280 ms
Minimum WDI Input Pulse Width
t
WDI
100
ns
V
IL
0.8
WDI Input Threshold
V
IH
2.0
V
WDI Input-Leakage Current V
WDI
= V
CC
or GND
-100 +100
nA
V
CC
Standby Current with WDI
Max Frequency
I
CCSW
Watchdog frequency = 1MHz,
V
CC
= V
CC(MAX)
, 1Hz, 32kHz outputs
disabled (Note 5)
450 µA
BATTERY TEST AND TRIP (Figures 17, 18, and 19)
V
BATT
Trip Point V
BTP
Internal mode
2.45
2.6
2.70
V
TRIP Input Threshold V
TRIP
V
CC
= V
CC(MAX)
, V
BATT
= 2V,
external mode
1.14 1.24 1.31
V
TRIP Input Comparator
Hysteresis
V
TRIP_HYST
10 mV
TRIP Input Current
I
TRIP_LKG
External mode
-100 +100
nA
Battery Test Load
R
LOAD_INT
Internal
0.50 0.91 1.30
M
TEST Output-High Voltage
V
TEST_HIGH
I
TEST
= -5mA
V
OUT
-
0.3V
V
TEST Output-Low Voltage
V
TEST_LOW
I
TEST
= 5mA 0.3 V
BATT_LO, ALM OUTPUT
V
BATT
= 2V, V
CC
= 0, I
OL
= 5mA 0.5
V
CC
= 2.7V, V
BATT
= 0, I
OL
= 10mA 0.5Output Low Voltage V
OL
V
CC
= 4.5V, V
BATT
= 0, I
OL
= 20mA 0.5
V
Off-Leakage I
LKG
-100 +100
nA
MAX6917
I
2
C-Compatible RTC with Microprocessor
Supervisor, Alarm, and NV RAM Controller
_______________________________________________________________________________________ 5
DC ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= V
CC(MIN)
to V
CC(MAX)
, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at T
A
= +25°C.) (Notes 1, 2)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX
UNITS
BATT_ON OUTPUT
V
BATT
= 2V, V
CC
= 0, I
OL
= 5mA 0.5
V
BATT
= 2.7V, V
CC
= 0, I
OL
= 10mA 0.5Output Low Voltage V
OL
V
BATT
= 4.5V, V
CC
= 0, I
OL
= 20mA 0.5
V
Off-Leakage I
LKG
-100 +100
nA
RESET
MAX6917EO30 2.5
2.63
2.7
MAX6917EO33 2.8
2.93
3.0RESET Threshold Voltage V
RST
MAX6917EO50 4.1
4.38
4.5
V
V
RST
Hysteresis V
HYST
30 mV
MAX6917EO30
27 75
MAX6917EO33
37 90V
CC
Falling-Reset Delay t
RPD
V
CC
falling from V
RST(MAX)
to V
RST(MIN)
, measured
from the beginning of V
CC
falling to RESET low
MAX6917EO50
50 120
µs
M ai n Reset Acti ve- Ti m eout P er i od
t
RP
140 200
280 ms
RESET Output Voltage V
OL
RESET asserted, I
OL
= 1.6mA, V
BATT
= 2V,
V
CC
= 0
0.2 V
Off-Leakage I
LKG
-100 +100
nA
I
2
C DIGITAL INPUTS SCL, SDA
Input High Voltage V
IH
0.7 x
V
CC
V
Input Low Voltage V
IL
0.3 x
V
CC
V
Input Hysteresis V
HYS
0.05 x
V
CC
V
Input Leakage Current V
IN
= 0 to V
CC
-100 +100
nA
Input Capacitance (Note 8) 10 pF
SDA Output Low Voltage V
OL
I
OL
= 4mA, V
CC
= V
CC(MIN)
0.4 V
FREQUENCY OUTPUTS (32kHz and 1Hz)
V
CC
= 0, V
BATT
= 2V,
I
OL
= 100µA
0.2
V
CC
= 2.7V, V
BATT
= 0,
I
OL
= 1mA
0.4
32kHz and 1Hz
OUT Low Voltage
V
OL
V
CC
= 4.5V, V
BATT
= 0,
I
OL
= 2mA
0.5
V
MAX6917
I
2
C-Compatible RTC with Microprocessor
Supervisor, Alarm, and NV RAM Controller
6 _______________________________________________________________________________________
Note 1: V
RST
is the reset threshold for V
CC
. See the Selector Guide section.
Note 2: All parameters are 100% tested at T
A
= +85°C. Limits overtemperature are guaranteed by design and are not
production tested.
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
FAST I
2
C-BUS TIMING (Figure 2 (Note 9))
SCL Clock Frequency f
SCL
(Note 10)
800 400,000
Hz
Bus Timeout
t
TIMEOUT
12s
Bus Free Time Between STOP
and START Conditions
t
BUF
1.3
µs
Hold Time After (Repeated)
START Conditions
t
HD:STA
After this period, the first clock is generated 0.6
µs
Repeated START Condition
Setup Time
t
HD:STA
0.6
µs
STOP Condition Setup Time
t
SU:STO
0.6
µs
Data Hold Time
t
HD:DAT
(Notes 11, 14) 0
0.9
µs
Data Setup Time
t
SU:DAT
100
ns
SCL Low Period t
LOW
1.3
µs
SCL High Period t
HIGH
0.6
µs
SCL/SDA Rise Time (Receiving)
t
R
(Note 12)
20 +
0.1 × C
b
300
ns
SCL/SDA Fall Time (Receiving) t
F
(Notes 12, 13)
20 +
0.1 × C
b
300
ns
SCL/SDA Fall Time (Transmitting)
t
F
(Notes 12, 13)
20 +
0.1 × C
b
250
ns
Pulse Width of Spike Suppressed
t
SP
0
50
ns
Capacitive Load for Each Bus
Line
C
b
400
pF
BATTERY-TEST TIMING (Figure 18)
Battery Test to BATT_LO Active t
BL
(Note 8) 1 s
Battery-Test CycleNormal t
BTCN
(Note 8) 24 hr
Battery-Test Pulse Width t
BTPW
(Note 8) 1 s
AC ELECTRICAL CHARACTERISTICS
(V
CC
= V
CC(MIN)
to V
CC(MAX)
, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
V
CC
= 0, V
BATT
= 2V,
I
OH
= -100µA
V
OUT
-
0.1V
V
CC
= 2.7V, V
BATT
= 0,
I
OH
= -1mA
V
OUT
-
0.3V
32kHz and 1Hz
OUT High Voltage
V
OH
V
CC
= 4.5V, V
BATT
= 0,
I
OH
= -2mA
V
OUT
-
0.4V
V
DC ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= V
CC(MIN)
to V
CC(MAX)
, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at T
A
= +25°C.) (Notes 1, 2)

MAX6917EO30+

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
IC RTC I2C COMPAT 20-QSOP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union