ADuM5400 Data Sheet
Rev. B | Page 6 of 16
IEC 60747-5-2 (VDE 0884, PART 2):2003-01 INSULATION CHARACTERISTICS
The ADuM5400 is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marking branded on the component denotes IEC 60747-5-2 (VDE 0884, Part 2) approval.
Table 8. VDE Characteristics
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
560 V
PEAK
Input-to-Output Test Voltage, Method b1 V
IORM
× 1.875 = V
pd(m)
, 100% production test, t
ini
= t
m
=
1 sec, partial discharge < 5 pC
V
pd(m)
1050 V
PEAK
Input-to-Output Test Voltage, Method a
After Environmental Tests Subgroup 1 V
IORM
× 1.5 = V
pd(m)
, t
ini
= 60 sec, t
m
= 10 sec, partial
discharge < 5 pC
V
pd(m)
840 V
PEAK
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
pd(m)
, t
ini
= 60 sec, t
m
= 10 sec, partial
discharge < 5 pC
V
pd(m)
672 V
PEAK
Highest Allowable Overvoltage V
IOTM
4000 V
PEAK
Withstand Isolation Voltage
1 minute withstand rating
V
ISO
2500
V
RMS
Surge Isolation Voltage V
PEAK
= 6 kV, 1.2 µs rise time, 50 µs, 50% fall time V
IOSM
6000 V
PEAK
Safety Limiting Values Maximum value allowed in the event of a failure
(see Figure 2)
Case Temperature T
S
150 °C
Side 1 I
DD1
Current I
S1
555 mA
Insulation Resistance at T
S
V
IO
= 500 V
R
S
>10
9
0
100
200
300
400
500
600
0 50 100 150 200
AMBIENT TEMPERATURE (°C)
SAFE OPERATING V
DD1
CURRENT (mA)
07509-003
Figure 2. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN EN 60747-5-2
RECOMMENDED OPERATING CONDITIONS
Table 9.
Parameter Symbol Min Max Unit
Operating Temperature Range T
A
−40 +105 °C
Supply Voltages
1
V
DD
4.5 5.5 V
1
Each voltage is relative to its respective ground.
Data Sheet ADuM5400
Rev. B | Page 7 of 16
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 10.
Parameter Rating
Storage Temperature (T
ST
) −55°C to +150°C
Ambient Operating Temperature (T
A
) −40°C to +85°C
Supply Voltages (V
DD1
, V
ISO
)
1
−0.5 V to +7.0 V
V
ISO
Supply Current
2
−40°C to +85°C 100 mA
−40°C to +105°C 60 mA
Input Voltage (V
IA
, V
IB
, V
IC
, V
ID
)
1, 3
−0.5 V to V
DDI
+ 0.5 V
Output Voltage (V
OA
, V
OB
, V
OC
, V
OD
)
1, 3
−0.5 V to V
ISO
+ 0.5 V
Average Output Current
per Data Output Pin
4
−10 mA to +10 mA
Common-Mode Transients
5
−100 kV/µs to +100 kV/µs
1
Each voltage is relative to its respective ground.
2
V
ISO
provides current for dc and dynamic loads on the Side 2 I/O channels.
This current must be included when determining the total V
ISO
supply
current.
3
V
DDI
and V
ISO
refer to the supply voltages on the input and output sides of
a given channel, respectively. See the PCB Layout section.
4
See Figure 2 for maximum rated current values for various temperatures.
5
Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the absolute maximum ratings may cause latch-up
or permanent damage.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
Table 11. Maximum Continuous Working Voltage Supporting 50-Year Minimum Lifetime
1
Parameter Max Unit Applicable Certification
AC Voltage, Bipolar Waveform 424 V peak All certifications, 50 year operation
AC Voltage, Unipolar Waveform
Basic Insulation 600 V peak Working voltage per IEC 60950-1
Reinforced Insulation 353 V peak Working voltage per IEC 60950-1
DC Voltage
Basic Insulation 600 V peak Working voltage per IEC 60950-1
Reinforced Insulation 353 V peak Working voltage per IEC 60950-1
1
Refers to the continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more information.
ADuM5400 Data Sheet
Rev. B | Page 8 of 16
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
V
DD1
1
GND
1
2
V
IA
3
V
IB
4
V
ISO
16
GND
ISO
15
V
OA
14
V
OB
13
V
IC
5
V
OC
12
V
ID
6
V
OD
11
V
DDL
7
V
ISO
10
GND
1
8
GND
ISO
9
ADuM5400
TOP VIEW
(Not to Scale)
07509-004
Figure 3. Pin Configuration
Table 12. Pin Function Descriptions
Pin No. Mnemonic Description
1 V
DD1
Primary Supply Voltage, 4.5 V to 5.5 V.
2, 8 GND
1
Ground 1. Ground reference for isolator primary. Pin 2 and Pin 8 are internally connected to each other,
and it is recommended that both pins be connected to a common ground.
3 V
IA
Logic Input A.
4 V
IB
Logic Input B.
5 V
IC
Logic Input C.
6 V
ID
Logic Input D.
7 V
DDL
Logic Power Supply Voltage. This pin must be connected to V
DD1
and have a dedicated bypass capacitor.
9, 15
GND
ISO
Ground Reference for Isolator Side 2. Pin 9 and Pin 15 are internally connected to each other, and it is
recommended that both pins be connected to a common ground.
10, 16 V
ISO
Secondary Supply Voltage Output for External Loads, 5.0 V. These pins are not tied together internally
and must be connected together on the PCB.
11 V
OD
Logic Output D.
12 V
OC
Logic Output C.
13 V
OB
Logic Output B.
14 V
OA
Logic Output A.
Table 13. Truth Table (Positive Logic)
V
Ix
Input
1
V
DD1
/V
DDL
State V
DD1
/V
DDL
Input (V) V
ISO
State V
ISO
Output (V) V
Ox
Output
1
Operation
High Powered 5.0 Powered 5.0 High Normal operation, data is high
Low Powered 5.0 Powered 5.0 Low Normal operation, data is low
1
V
Ix
and V
Ox
refer to the input and output signals of a given channel (A, B, C, or D).

ADUM5400ARWZ

Mfr. #:
Manufacturer:
Analog Devices / Linear Technology
Description:
Digital Isolators Quad-CH w/ Intg DC/DC Converter
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet