MAX2361/MAX2363/MAX2365
Complete Dual-Band
Quadrature Transmitters
_______________________________________________________________________________________ 5
Note 1: Guaranteed by design and characterization to 3 sigma (includes board and component variations).
Note 2: ACPR is met over the specified V
CM
range.
Note 3: V
CM
must be supplied by the I/Q baseband source with ±8µA capability.
Note 4: IQ_LEVEL = 0, V
Q
_ = V
I
_ = 87mV
RMS
differential, IS98 reverse channel modulation at 415mVp-p differential with 0.1% 4.5dB
peak-to-average ratio.
Note 5: When enabled with RCP_TURBO1 and RCP_TURBO2 (see Tables 2 and 3), the total charge-pump current is specified. For all
values of RCP, the total turbolock current is 1.63 times the corresponding nonturbo current value.
ELECTRICAL CHARACTERISTICS (continued)
(MAX2361/MAX2363/MAX2365 EV kit, 50Ω system, operating modes as defined in Table 9, TEMP_COMP = 10, input voltage at I
and Q = 600mV
P-P
differential, 300kHz quadrature CW tones, RF and IF synthesizers locked, V
REF
= 200mV
P-P
at 19.68MHz, V
CC
=
V
BAT
= SHDN = IDLE = CS = TXGATE = 2.8V, LOH, LOL input power = -10dBm, f
LOL
= 966.38MHz, f
LOH
= 1750MHz, f
RFH0
= f
RFH1
= 1880.38MHz, f
RFL
= 836MHz, T
A
= +25°C, unless otherwise noted.)
987 µA
Charge-Pump Source/Sink
Matching
All values of ICP, over specified compliance range 6 %
IF Charge-Pump Compliance 0.5
µA
Charge-Pump Source/Sink
Matching
All values of RCP, over specified compliance range 6 %
RF Charge Pump Compliance 0.5
- 0.5
V
Phase Detector Noise Floor
RCP = 11, RCP_TURBO1 = RCP_TURBO2 = 0,
30kHz comparison frequency