MAX6872/MAX6873
EEPROM-Programmable, Hex/Quad,
Power-Supply Sequencers/Supervisors
______________________________________________________________________________________ 13
Table 1. Programmable Features
FEATURE DESCRIPTION
High-Voltage Input
(IN1)
Primary undervoltage threshold
Secondary overvoltage or undervoltage threshold
+2.5V to +13.2V threshold in 50mV increments
+1.25V to +7.625V threshold in 25mV increments
Bipolar-Voltage Input
(IN2)
Primary undervoltage threshold
Secondary overvoltage or undervoltage threshold
±2.5V to ±15.25V threshold in 50mV increments
±1.25V to ±7.625V threshold in 25mV increments
Positive-Voltage Input
IN3–IN6 (MAX6872),
IN3–IN4 (MAX6873)
Primary undervoltage threshold
Secondary overvoltage or undervoltage threshold
+1V to +5.5V threshold in 20mV increments
+0.5V to +3.05V threshold in 10mV increments
Programmable Outputs
PO1–PO4 (MAX6872),
PO1–PO2 (MAX6873)
Active high or active low
Open-drain, weak pullup, or charge-pump output
Weak pullup to IN3–IN6 (IN3 or IN4 for MAX6873) or ABP
Dependent on MR, MARGIN, IN_, GPI1–GPI4 , WD1 and WD2, and/or PO_
Programmable timeout periods of 25µs, 1.5625ms, 6.25ms, 25ms, 50ms, 200ms, 400ms, or 1.6s
Programmable Outputs
PO5–PO8 (MAX6872),
PO3–PO5 (MAX6873)
Active high or active low
Open-drain, weak pullup, or push-pull output
Weak pullup to IN3–IN6 (IN3 or IN4 for MAX6873) or ABP
Push-pull to IN3–IN6 (IN3 or IN4 for MAX6873)
Dependent on MR, MARGIN, IN_, GPI1–GPI4 , WD1 and WD2, and/or PO_
Programmable timeout periods of 25µs, 1.5625ms, 6.25ms, 25ms, 50ms, 200ms, 400ms, or 1.6s
General-Purpose Logic
Inputs (GPI1–GPI4)
Active high or active low logic levels
Configure GPI_ as inputs to watchdog timers or programmable output stages
Watchdog Timers
Clear dependent on any combination of one GPI_ input and one programmable output, a GPI_ input
only, or a programmable output only
Initial watchdog timeout period of 6.25ms, 25ms, 100ms, 400ms, 1.6s, 6.4s, 25.6s, or 102.4s
Normal watchdog timeout period of 6.25ms, 25ms, 100ms, 400ms, 1.6s, 6.4s, 25.6s, or 102.4s
Watchdog enable/disable
Initial watchdog timeout period enable/disable
Manual Reset Input
(MR)
Forces PO_ into the active output state when MR = GND
PO_ deassert after MR releases high and the PO_ timeout period expires
PO_ cannot be a function of MR only
Margining Input
(MARGIN)
Holds PO_ in existing state or asserts PO_ to a programmed output state, independent of changes in
monitored inputs or watchdog timers, when MARGIN = GND
Overrides MR when both assert at the same time
Write Disable Locks user EEPROM based on PO_
Configuration Lock Locks configuration EEPROM
where V
TH
is the desired threshold voltage and x is the
decimal code for the desired threshold (Table 3).
IN3–IN6
IN3–IN6 offer positive voltage detectors monitor volt-
ages from +1V to +5.5V in 20mV increments, or +0.5V
to +3.05V in 10mV increments. Use the following equa-
tions to set the threshold voltages for IN_:
where V
TH
is the desired threshold voltage and x is the
decimal code for the desired threshold (Table 4). For
the +1V to +5.5V range, x must equal 225 or less, oth-
x
VV
V
for V to V range
TH
=++
.
.
. .
05
001
05 305
x
VV
V
for V to V range
TH
=++
.
.
1
002
155
x
VV
V
for V to V range
TH
=++
.
.
. .
125
0 025
1 25 7 625
x
VV
V
for V to V range
TH
=++
.
.
. .
25
005
2 5 15 25
x
VV
V
for V to V range
TH
=
()
−−
−− .
.
. .
125
0 025
1 25 7 625
MAX6872/MAX6873
EEPROM-Programmable, Hex/Quad,
Power-Supply Sequencers/Supervisors
14 ______________________________________________________________________________________
Table 3. IN2 Threshold Settings
REGISTER
ADDRESS
EEPROM
MEMORY
ADDRESS
BIT
RANGE
DESCRIPTION
01h 8001h [7:0]
IN2 primary undervoltage detector threshold (V2A) (see equations in the Bipolar-Voltage
Input (IN2) section).
07h 8007h [7:0]
IN2 secondary undervoltage/overvoltage detector threshold (V2B) (see equations in the
Bipolar-Voltage Input (IN2) section).
0Ch 800Ch [1]
IN2 secondary overvoltage/undervoltage selection:
0 = overvoltage threshold. 1 = undervoltage threshold.
0Dh 800Dh [7:6]
IN2 range selection:
00 = -2.5V to -15.25V range in 50mV increments.
01 = -1.25V to -7.625V range in 25mV increments.
10 = +2.5V to +15.25V range in 50mV increments.
11 = +1.25V to +7.625V range in 25mV increments.
Table 2. IN1 Threshold Settings
REGISTER
ADDRESS
EEPROM
MEMORY
ADDRESS
BIT
RANGE
DESCRIPTION
00h 8000h [7:0]
IN1 primary undervoltage detector threshold (V1A) (see equations in the High-Voltage Input
(IN1) section).
06h 8006h [7:0]
IN1 secondary undervoltage/overvoltage detector threshold (V1B) (see equations in the
High-Voltage Input (IN1) section).
0Ch 800Ch [0]
IN1 secondary overvoltage/undervoltage selection:
0 = overvoltage threshold. 1 = undervoltage threshold.
0Dh 800Dh [0]
IN 1 r ang e sel ecti on:
0 = 2.5V to 13.2V r ang e i n 50m V i ncr em ents. 1 = 1.25V to 7.625V r ang e i n 25m V i ncr em ents.
MAX6872/MAX6873
EEPROM-Programmable, Hex/Quad,
Power-Supply Sequencers/Supervisors
______________________________________________________________________________________ 15
Table 4. IN3–IN6 Threshold Settings
REGISTER
ADDRESS
EEPROM
MEMORY
ADDRESS
BIT
RANGE
DESCRIPTION
02h 8002h [7:0] IN3 primary undervoltage detector threshold (V3A) (see equations in the IN3–IN6 section).
03h 8003h [7:0] IN4 primary undervoltage detector threshold (V4A) (see equations in the IN3–IN6 section).
04h 8004h [7:0]
IN5 (MAX6872 only) primary undervoltage detector threshold (V5A)
(see equations in the IN3–IN6 section).
05h 8005h [7:0]
IN6 (MAX6872 only) primary undervoltage detector threshold (V6A)
(see equations in the IN3–IN6 section).
08h 8008h [7:0]
IN3 secondary undervoltage/overvoltage detector threshold (V3B)
(see equations in the IN3–IN6 section).
09h 8009h [7:0]
IN4 secondary undervoltage/overvoltage detector threshold (V4B)
(see equations in the IN3–IN6 section).
0Ah 800Ah [7:0]
IN5 (MAX6872 only) secondary undervoltage/overvoltage detector threshold (V5B)
(see equations in the IN3–IN6 section).
0Bh 800Bh [7:0]
IN6 (MAX6872 only) secondary undervoltage/overvoltage detector threshold (V6B)
(see equations in the IN3–IN6 section).
[2]
IN3 secondary overvoltage/undervoltage selection.
0 = overvoltage threshold. 1 = undervoltage threshold.
[3]
IN4 secondary overvoltage/undervoltage selection.
0 = overvoltage threshold. 1 = undervoltage threshold.
[4]
IN5 (MAX6872 only) secondary overvoltage/undervoltage selection.
0 = overvoltage threshold. 1 = undervoltage threshold.
[5]
IN6 (MAX6872 only) secondary overvoltage/undervoltage selection.
0 = overvoltage threshold. 1 = undervoltage threshold.
0Ch 800Ch
[7:6] Not used.
[1]
IN 3 r ang e sel ecti on.
0 = + 1V to + 5.5V r ang e i n 20m V i ncr em ents. 1 = + 0.5V to + 3.05V r ang e i n 10m V i ncr em ents.
[2]
IN 4 r ang e sel ecti on.
0 = + 1V to + 5.5V r ang e i n 20m V i ncr em ents. 1 = + 0.5V to + 3.05V r ang e i n 10m V i ncr em ents.
[3]
IN 5 ( M AX 6872 onl y) r ang e sel ecti on.
0 = + 1V to + 5.5V r ang e i n 20m V i ncr em ents. 1 = + 0.5V to + 3.05V r ang e i n 10m V i ncr em ents.
[4]
IN 6 ( M AX 6872 onl y) r ang e sel ecti on.
0 = + 1V to + 5.5V r ang e i n 20m V i ncr em ents. 1 = + 0.5V to + 3.05V r ang e i n 10m V i ncr em ents.
0Dh 800Dh
[5] Not used.
erwise the threshold exceeds the maximum operating
voltage of IN3–IN6.
GPI1–GPI4
The GPI1–GPI4 programmable logic inputs control
power-supply sequencing (programmable outputs),
reset/interrupt signaling, and watchdog functions (see
the Configuring the Watchdog Timers (Registers
3Ch–3Fh) section). Configure GPI1–GPI4 for active-low
or active-high logic (Table 5). GPI1–GPI4 internally pull
down to GND through a 10µA current sink.

MAX6872ETJ+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Supervisory Circuits EEPROM-Prog Hex Power-Sup Sequence
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet