TJA1082 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet Rev. 6 — 28 November 2012 23 of 38
NXP Semiconductors
TJA1082
FlexRay node transceiver
10. Dynamic characteristics
Table 12. Dynamic characteristics
All parameters are guaranteed for V
CC
= 4.5 V to 5.25 V; V
IO
= 2.6 V to 5.25 V; T
vj
=
40
C to +150
C and R
bus
= 45
unless otherwise specified. All voltages are defined with respect to ground; positive currents flow into the IC.
Symbol Parameter Conditions Min Typ Max Unit
Pins BP and BM
t
d(TXD-bus)
delay time from TXD to bus Normal mode
[1][2]
DATA_0 - - 50 ns
DATA_1 - - 50 ns
t
d(TXD-bus)
delay time difference from TXD to bus Normal mode; between
DATA_0 and DATA_1
[1][2]
4- +4ns
t
d(bus-RXD)
delay time from bus to RXD Normal mode; C
RXD
= 15 pF;
(V
BP
+V
BM
)/2 = 2.5 V
[3]
DATA_0 - - 50 ns
DATA_1 - - 50 ns
Normal mode; C
RXD
= 25 pF;
(V
BP
+V
BM
)/2 = 2.5 V
[3]
DATA_0 - - 60 ns
DATA_1 - - 60 ns
t
d(bus-RXD)
delay time difference from bus to RXD Normal mode; between
DATA_0 and DATA_1;
(V
BP
+V
BM
)/2 = 2.5 V
[3]
C
RXD
= 15 pF 5- 5 ns
C
RXD
= 25 pF 6- 6 ns
t
d(TXEN-busidle)
delay time from TXEN to bus idle Normal mode; V
TXD
= 0 V - - 75 ns
t
d(TXEN-busact)
delay time from TXEN to bus active Normal mode; V
TXD
= 0 V - - 75 ns
t
d(TXEN-bus)
delay time difference from TXEN to bus
(absolute value)
Normal mode; between TXEN
to bus active and TXEN to
bus idle; V
TXD
= 0 V
[4]
50 ns
t
d(BGE-busidle)
delay time from BGE to bus idle Normal mode; V
TXD
= 0 V - - 75 ns
t
d(BGE-busact)
delay time from BGE to bus active Normal mode; V
TXD
= 0 V - - 75 ns
t
r(dif)(bus)
bus differential rise time DATA_0 to DATA_1;
20 % to 80 %; R
bus
= 45 ;
C
bus
= 100 pF
[5]
3.75 - 18.75 ns
t
f(dif)(bus)
bus differential fall time DATA_1 to DATA_0;
80 % to 20 %; R
bus
= 45 ;
C
bus
= 100 pF
[5]
3.75 - 18.75 ns
t
(r-f)(dif)
difference between differential rise and
fall time
on bus; 80 % to 20 %
R
bus
= 45 ; C
bus
= 100 pF
[5]
3- 3 ns
t
f(bus)(idle-act)
bus fall time from idle to active bus idle to DATA_0;
R
bus
= 45 ; C
bus
= 100 pF;
30 mV > V
dif
> 300 mV
[5][6]
- - 30 ns
t
f(bus)(act-idle)
bus fall time from active to idle DATA_1 to bus idle;
R
bus
= 45 ; C
bus
= 100 pF;
300 mV > V
dif
> 30 mV
[5][6]
- - 30 ns