During the start-up sequence:
When the TDF8599A is switched from standby to mute (t
d(stb-mute)
). When a short
circuit on one of the output terminals (i.e. between V
P
or GND) is detected, the
start-up procedure is interrupted and the TDF8599A waits for open circuit outputs.
No large currents flow in the event of a short circuit to the supply lines because the
check is performed before the power stages are enabled.
During operation:
A short to one of the supply lines trips OCP causing the amplifier channel to
shutdown. After 50 ms the amplifier channel restarts and WP is activated.
However, the corresponding amplifier channel will not start-up until the supply line
short circuit has been removed.
8.5.5 DC offset protection
DC Protection (DCP) is activated when the DC content in the demodulated output voltage
exceeds a set threshold (typically 2 V). DCP is active in both Mute mode and Operating
mode. Figure 14 shows how false triggering of the DCP by low frequencies in the audio
signal is prevented using the external capacitor (C
F
) to generate a cut-off frequency.
In I
2
C-bus mode, DC offsets generate a voltage shift around the bias voltage. When the
voltage shift exceeds threshold values, the offset alarm bit DB1[D2] is set and if bit
IB1[D7] is not set, diagnostic information is also given. Any detected offset shuts down
both channels when bit IB2[D7] is not set. To restart the TDF8599A in I
2
C-bus mode, pin
EN must be toggled or DCP disabled by connecting pin DCP to pin AGND.
Fig 14. DC offset protection and diagnostic output
001aak078
OUT1P
OUT1N
V to I
OUT2P
OUT2N
DCP
DIAG
switch off channels
IB1[D6] IB2[D6]
V to I
V
ref
SQ
DB1[D2]
IB1[D7]
IB2[D7]
S4
50 k
S3
C
F
TDF8599A_2 © NXP B.V. 2009. All rights reserved.
Product data sheet Rev. 02 — 30 June 2009 17 of 54
NXP Semiconductors
TDF8599A
I
2
C-bus controlled dual channel class-D power amplifier
In non-I
2
C-bus mode, when an offset is detected, DCP always gives diagnostic
information on pin DIAG and shuts down both channels.
Connecting a capacitor between pins DCP and AGND enables DC offset protection.
Connecting pin DCP to pin AGND disables DCP in both I
2
C-bus and non-I
2
C-bus mode.
8.5.6 Supply voltages
UnderVoltage Protection (UVP) is activated when the supply voltage drops below the UVP
threshold. UVP triggers the UVP circuit causing the system to first mute and then stop
switching. When the supply voltage rises above the threshold level, the system restarts.
OverVoltage Protection (OVP) is activated when the supply voltage exceeds the OVP
threshold. The OVP (or load dump) circuit is activated and the power stages are
shutdown.
An overview of all protection circuits and the amplifier states is given in Table 10.
8.5.7 Overview of protection circuits and amplifier states
[1] When fault is removed.
[2] Amplifier gain depends on the junction temperature and size of the heat sink.
[3] TFP influences restart timing depending on heat sink size.
[4] Shorted load causes a restart of the channel every 50 ms.
[5] Latched protection is reset by toggling pin EN or by disabling DCP in I
2
C-bus mode.
[6] In I
2
C-bus mode deep supply voltage drops will cause a Power-On Reset (POR). The restart requires an
I
2
C-bus command.
8.6 Diagnostic output
8.6.1 Diagnostic table
The diagnostic information for I
2
C-bus mode and non-I
2
C-bus mode is shown in Table 11.
The instruction bitmap and data bytes are described in Table 14 and Table 15.
Pins DIAG and CLIP have an open-drain output which must have an external pull-up
resistor connected to an external voltage. Pins CLIP and DIAG can show both fixed and
I
2
C-bus selectable information.
Table 10. Overview of TDF8599A protection circuits and amplifier states
Protection circuit name Amplifier state
Complete
shutdown
Channel
shutdown
Restart
[1]
TFP N
[2]
N
[2]
Y
[3]
OTP Y N Y
[3]
OCP N Y Y
[4]
WP N Y Y
DCP Y N N
[5]
UVP Y N Y
[6]
OVP Y N Y
TDF8599A_2 © NXP B.V. 2009. All rights reserved.
Product data sheet Rev. 02 — 30 June 2009 18 of 54
NXP Semiconductors
TDF8599A
I
2
C-bus controlled dual channel class-D power amplifier
Pin DIAG goes LOW when a short circuit to one of the amplifier outputs occurs. The
microprocessor reads the failure information using the I
2
C-bus. The I
2
C-bus bits are set
for a short circuit. These bits can be reset with the I
2
C-bus read command.
Even after the short has been removed, the microprocessor knows what was wrong after
reading the I
2
C-bus. Old information is read when a single I
2
C-bus read command is
used. To read the current information, two read commands must be sent, one after
another.
When selected, pin DIAG gives the current diagnostic information. Pin DIAG is released
instantly when the failure is removed, independent of the I
2
C-bus latches.
When OCP is triggered, the open-drain DIAG output is activated. The diagnostic output
signal during different short circuit conditions is illustrated in Figure 15.
8.6.2 Load identification (I
2
C-bus mode only)
8.6.2.1 DC load detection
DC load detection is only available in I
2
C-bus mode and is controlled using bit IB2[D2].
The default setting is logic 0 for bit IB2[D2] which disables DC load detection. DC load
detection is enabled when bit IB2[D2] = 1. Load detection takes place before the class-D
amplifier output stage starts switching in Mute mode and the start-up time from Standby
mode to Mute mode is increased by t
det(DCload)
(see Figure 16).
Table 11. Available data on pins DIAG and CLIP
Diagnostic I
2
C-bus mode Non-I
2
C-bus mode
Pin DIAG Pin CLIP Pin DIAG Pin CLIP
Power-on reset yes yes yes yes
UVP or OVP yes no yes no
Clip detection no selectable no yes
Temperature pre-warning no selectable no yes
OCP/WP yes no yes no
DCP selectable no yes no
OTP yes no yes no
Fig 15. Diagnostic output for short circuit conditions
001aai786
AMPLIFIER
RESTART
shorted load
pull up V
AGND = 0 V
50 ms
50 ms50 ms
NO
RESTART