ADGS1612 Data Sheet
Rev. 0 | Page 8 of 29
Parameter 25°C −40°C to +85°C −40°C to +125°C Unit Test Conditions/Comments
Total Harmonic Distortion Plus Noise,
THD + N
0.093 % typ
R
L
= 110 Ω, f = 20 Hz to 20 kHz,
V
S
= 3.5 V p-p ; see Figure 33
−3 dB Bandwidth 38 MHz typ R
L
= 50 Ω, C
L
= 5 pF; see Figure 34
Insertion Loss −0.15 dB typ
R
L
= 50 Ω, C
L
= 5 pF, f = 1 MHz; see
Figure 34
Off Switch Source Capacitance, C
S
(Off) 72 pF typ V
S
= 2.5 V, f = 1 MHz
Off Switch Drain Capacitance, C
D
(Off) 72 pF typ V
S
= 2.5 V, f = 1 MHz
On Switch Capacitance, C
D
(On), C
S
(On) 160 pF typ V
S
= 2.5 V, f = 1 MHz
POWER REQUIREMENTS
V
DD
= 5.5 V
Positive Supply Current, I
DD
0.01 μA typ All switches open
1 μA max
0.01 μA typ All switches closed, V
L
= 5.5 V
1 μA max
130 μA typ All switches closed, V
L
= 2.7 V
220 μA max
Digital Supply Current, I
L
Inactive 6.3 μA typ Digital inputs = 0 V or V
L
8.0 μA max
Inactive, SCLK = 1 MHz 14 μA typ
CS
E
= V
L
and SDI = 0 V or V
L
,
V
L
= 5 V
7 μA typ
CS
E
= V
L
and SDI = 0 V or V
L
,
V
L
= 3 V
SCLK = 50 MHz 390 μA typ
CS
E
= V
L
and SDI = 0 V or V
L
,
V
L
= 5 V
210 μA typ
CS
E
= V
L
and SDI = 0 V or V
L
,
V
L
= 3 V
Inactive, SDI = 1 MHz 15 μA typ
CS
E
and SCLK = 0 V or V
L
, V
L
= 5 V
7.5 μA typ
CS
E
and SCLK = 0 V or V
L
, V
L
= 3 V
SDI = 25 MHz 230 μA typ
CS
E
and SCLK = 0 V or V
L
, V
L
= 5 V
120 μA typ
CS
E
and SCLK = 0 V or V
L
, V
L
= 3 V
Active at 50 MHz 1.8 mA typ
Digital inputs toggle between 0 V
and V
L
, V
L
= 5.5 V
2.1 mA max
0.7 mA typ
Digital inputs toggle between 0 V
and V
L
, V
L
= 2.7 V
1.0 mA max
V
DD
3.3 V min GND = 0 V, V
SS
= 0 V
16 V max GND = 0 V, V
SS
= 0 V