Table 1. Recommended Operating Conditions
Parameter Symbol Test Condition
Min
1
Typ
Max
1
Unit
Ambient Temperature T
A
–40 25 85 °C
Si5017 Supply Voltage
2
V
DD
3.135 3.3 3.465 V
Notes:
1. All minimum and maximum specifications are guaranteed and apply across the recommended operating conditions.
Typical values apply at nominal supply voltages and an operating temperature of 25 °C unless otherwise stated.
2. The Si5017 specifications are guaranteed when using the recommended application circuit (including component
tolerance) of the "Typical Application Schematic" on page 11.