DC and AC parameters STM1404
24/36
7 DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 5: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Figure 24. AC testing input/output waveforms
Figure 25. MR
timing waveform
Table 5. Operating and AC measurement conditions
Parameter STM1404 Unit
V
CC
/V
BAT
supply voltage 2.2 to 3.6 V
Ambient operating temperature (T
A
)–40 to 85°C
Input rise and fall times ≤ 5ns
Input pulse voltages 0.2 to 0.8V
CC
V
Input and output timing ref. voltages 0.3 to 0.7V
CC
V
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
AI09694
RST
MR
tMLRL
trec
tMLMH