STM1404 DC and AC parameters
25/36
Figure 26. STM1404 switchover diagram, condition A (V
BAT
< V
SW
)
Figure 27. STM1404 switchover diagram, condition B (V
BAT
> V
SW
)
AI10463
V
CC
= 3.3V
V
SW
= 2.4V
V
BAT
V
BAT
– 75mV
V
BAT
– 35mV
V
RST
V
OUT
AI10464
V
CC
= 3.3V
V
SW
= 2.4V
V
BAT
V
SW
+ 40mV
V
OUT
Table 6. DC and AC characteristics
Sym
Alter-
native
Description Test condition
(1)
Min Typ Max Unit
V
CC
,
V
BAT
(2)
Operating voltage T
A
= –40 to +85°C 2.2 3.6 V
I
CC
V
CC
supply current
(STM1404A)
Typ @ 3.3 V, 25°C
50 65 µA
V
CC
supply current
(STM1404B,C)
35 50 µA
V
CC
supply current in
battery backup mode
Excluding I
OUT
(V
BAT
= 2.3 V, V
CC
= 2.0
V, M R = V
CC
)
25 35 µA
I
BAT
(3)
V
BAT
supply current in
battery backup mode
Excluding I
OUT
(V
BAT
= 3.6 V)
5.3 8.0 µA
V
OUT1
V
OUT
voltage (active)
I
OUT1
= 5 mA
(4)
(V
CC
> V
SW
)
V
CC
– 0.03
V
CC
0.015
V
I
OUT1
= 80 mA
(V
CC
> V
SW
)
V
CC
– 0.3 V
CC
– 0.15 V
I
OUT1
= 250 µA,
V
CC
> V
SW
(4)
V
CC
0.0015
V
CC
0.0006
V
V
OUT2
V
OUT
voltage
(battery
backup)
I
OUT2
= 250 µA,
V
BAT
= 2.2 V
V
BAT
– 0.1 V
BAT
– 0.04 V
I
OUT2
= 1 mA,
V
BAT
= 2.2 V
V
BAT
– 0.16 V
V
TPU1
Internal switched
supply voltage (active)
I
SOURCE
= 5 mA
(V
CC
> V
SW
)
V
CC
– 0.3 V
DC and AC parameters STM1404
26/36
V
TPU2
Internal switched
supply voltage (battery
backup)
I
SOURCE
= 1 mA
(V
BAT
= 2.2 V)
V
BAT
– 0.10 V
I
LI
Input leakage current
(MR)
MR
= 0 V; V
CC
= 3V 20 75 350 µA
Input leakage current
(PFI)
0 V = V
IN
= V
CC
–25 2 +25 nA
Input leakage current
(TP1-TP4)
0 V = V
IN
= V
CC
–1 +1 µA
I
LO
Output leakage current 0 V = V
IN
= V
CC
(5)
–1 +1 µA
V
IH
Input high voltage (MR)
V
RST
(max) < V
CC
< 3.6 V
0.7V
CC
V
V
IL
Input low voltage (MR)0.3V
CC
V
V
OL
Output low voltage
(PFO, RST, Vccsw,
SAL
, BLD)
V
CC
= V
RST
(max),
I
SINK
= 3.2 mA
0.3 V
V
OL
Output low voltage
(RST)
I
OL
= 40 µA; V
CC
= 1.0 V;
V
BAT
= V
CC
;
T
A
= 0°C to 85°C
0.3 V
I
OL
= 200 µA;
V
CC
= 1.2 V; V
BAT
= V
CC
0.3 V
Table 6. DC and AC characteristics (continued)
Sym
Alter-
native
Description Test condition
(1)
Min Typ Max Unit
STM1404 DC and AC parameters
27/36
V
OHB
V
OH
battery backup
(Vccsw)
I
SOURCE
= 100 µA 0.8V
BAT
V
Pull-up supply voltage
(open drain)
RST
, SAL, BLD, PFO 3.6 V
Power-fail comparator
V
PFI
PFI input threshold PFI falling (V
CC
< 3.6 V) 1.212 1.237 1.262 V
PFI hysteresis PFI rising (V
CC
< 3.6 V) 10 20 mV
t
PFD
PFI to PFO
propagation delay
s
Battery switchover
V
SO
Battery backup
switchover voltage
(6)(7)
Power-
down
V
BAT
> V
SW
V
SW
V
V
BAT
< V
SW
V
BAT
V
Power-up
V
BAT
> V
SW
V
SW
V
V
BAT
< V
SW
V
BAT
V
V
SW
2.4 V
Hysteresis 40 mV
Battery low voltage detect
V
DET
Battery detect
threshold
On power-
up only
M 2.25 2.30 2.34 V
N 2.45 2.50 2.55 V
O 3.14 3.20 3.26 V
Voltage reference (option for STM1404A)
(8)
V
REF
Voltage reference (see
Section 2.9: V
REF
,
reference voltage
output (1.237, typ) on
page 13)
0°C to 85°C 1.212 1.237 1.262 V
–40° to 0°C 1.200 1.237 1.274 V
I
REF+
Source current
0°C to 85°C 15 25 µA
–40° to 0°C 10 15 µA
I
REF–
Sink current 10 13 µA
V
n
Output voltage noise f = 100 Hz to 100 kH 10-100 µV
rms
Table 6. DC and AC characteristics (continued)
Sym
Alter-
native
Description Test condition
(1)
Min Typ Max Unit

STM1404ATOHQ6F

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
Supervisory Circuits 3V FIPS 140 Security supervisor
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union