DC and AC parameters M41T00AUD
34/42 Doc ID 13480 Rev 5
10 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Figure 17. AC testing input/output waveform
Table 10. Operating and AC measurement conditions
(1)
1. Output Hi-Z is defined as the point where data is no longer driven.
Parameter M41T00AUD
Supply voltage (V
CC
) 3.0 to 3.6 V
Ambient operating temperature (T
A
) 0 to 70 °C
Digital load capacitance (C
L
) 100 pF
Audio load resistance (R
L
) ≥ 8 Ω
Digital input rise and fall times
≤
5 ns
Digital input pulse voltages 0.2V
CC
to 0.8V
CC
Digital input and output timing reference voltages 0.3V
CC
to 0.7V
CC
Table 11. Input/output characteristics (25 °C, f = 1 MHz)
Symbol
Parameter
(1)
1. Effective capacitance measured with power supply at 3.3 V; sampled only, not 100% tested
Min Max Unit
C
IND
Input capacitance, digital inputs 7 pF
C
OUTD
(2)
2. Outputs deselected
Output capacitance, digital outputs 10 pF
t
LP
I
2
C low-pass filter input time constant (SDA and SCL)
50 ns
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC