ICS1894-34
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH MII INTERFACE PHYCEIVER
IDT®
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH MII INTERFACE 28
ICS1894-34 REV B 052112
DC and AC Operating Conditions
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS1894-34. These ratings, which are
standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at these
or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical
parameters are guaranteed only over the recommended operating temperature range.
Recommended Operating Conditions
Parameter Rating
VDD (measured to VSS) -0.3 V to 3.6V
Digital Inputs / Outputs -0.3 V to VDD +0.3 V
Storage Temperature -55° C to +150° C
Junction Temperature 125° C
Soldering Temperature 260° C
Power Dissipation See section “DC Operating Conditions for Supply Current”
Parameter Symbol Min. Max. Units
Ambient Operating Temperature - Commercial T
A
0+70°C
Ambient Operating Temperature - Industrial T
A
-40 +85 ° C
Power Supply Voltage (measured to VSS) VDD +3.14 +3.47 V