©2014 Silicon Storage Technology, Inc. DS20005020B 07/14
13
32 Mbit Multi-Purpose Flash Plus
SST39VF3201C / SST39VF3202C
Data Sheet
Security ID
The SST39VF3201C/3202C devices offer a 136 word Security ID space. The Secure ID space is
divided into two segments - one factory programmed segment and one user programmed segment.
The first segment is programmed and locked at Microchip with a random 128-bit number. The 128-
word user segment is left un-programmed for the customer to program as desired.
To program the user segment of the Security ID, the user must use the Security ID Word-Program
command. To detect end-of-write for the SEC ID, read the toggle bits. Do not use Data# Polling. Once
this is complete, the Sec ID should be locked using the User Sec ID Program Lock-Out. This disables
any future corruption of this space. Note that regardless of whether or not the Sec ID is locked, neither
Sec ID segment can be erased.
The Secure ID space can be queried by executing a three-byte command sequence with Enter Sec ID
command (88H) at address 555H in the last byte sequence. To exit this mode, the Exit Sec ID com-
mand should be executed. Refer to Table 7 for more details.
©2014 Silicon Storage Technology, Inc. DS20005020B 07/14
14
32 Mbit Multi-Purpose Flash Plus
SST39VF3201C / SST39VF3202C
Data Sheet
Operations
Table 6: Operation Modes Selection
Mode CE# OE# WE# DQ Address
Read V
IL
V
IL
V
IH
D
OUT
A
IN
Program V
IL
V
IH
V
IL
D
IN
A
IN
Erase V
IL
V
IH
V
IL
X
1
1. X can be V
IL
or V
IH
, but no other value.
Sector or block address,
XXH for Chip-Erase
Standby V
IH
X X High Z X
Write Inhibit X V
IL
X High Z/ D
OUT
X
XXV
IH
High Z/ D
OUT
X
Product Identification
Software Mode V
IL
V
IL
V
IH
See Table 7
T6.0 20005020
Table 7: Software Command Sequence
Command
Sequence
1st Bus
Write Cycle
2nd Bus
Write Cycle
3rd Bus
Write Cycle
4th Bus
Write Cycle
5th Bus
Write Cycle
6th Bus
Write Cycle
Addr
1
1. Address format A
10
-A
0
(Hex).
Addresses A
11
-A
20
can be V
IL
or V
IH,
but no other value, for Command sequence for SST39VF3201C/3202C.
Data
2
2. DQ
15
-DQ
8
can be V
IL
or V
IH
, but no other value, for Command sequence
Addr
1
Data
2
Addr
1
Data
2
Addr
1
Data
2
Addr
1
Data
2
Addr
1
Data
2
Word-Program
555H AAH 2AAH 55H 555H A0H WA
3
3. WA = Program Word address
Data
Sector-Erase
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H SA
X
4
4. SA
X
for Sector-Erase; uses A
MS
-A
11
address lines
BA
X
, for Block-Erase; uses A
MS
-A
15
address lines
A
MS
= Most significant address
A
MS
=A
20
for SST39VF3201C/3202C
50H
Block-Erase
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H BA
X
4
30H
Chip-Erase
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H 555H 10H
Erase-Suspend
XXXXH
B0H
Erase-Resume
XXXXH
30H
Query Sec ID
5
555H AAH 2AAH 55H 555H 88H
User Security ID
Word-Program
555H AAH 2AAH 55H 555H A5H WA
6
Data
User Security ID
Program Lock-Out
555H AAH 2AAH 55H 555H 85H XXH
6
0000H
Software ID
Entry
7,8
555H AAH 2AAH 55H 555H 90H
CFI Query Entry
555H AAH 2AAH 55H 555H 98H
CFI Query Entry
55H 98H
Software ID Exit
9,10
/CFI Exit/Sec ID
Exit
555H AAH 2AAH 55H 555H F0H
Software ID Exit
9,10
/CFI Exit/Sec ID
Exit
XXH F0H
T7.0 20005020
©2014 Silicon Storage Technology, Inc. DS20005020B 07/14
15
32 Mbit Multi-Purpose Flash Plus
SST39VF3201C / SST39VF3202C
Data Sheet
5. With A
MS
-A
4
= 0; Sec ID is read with A
3
-A
0
,
Microchip ID is read with A
3
= 0 (Address range = 000000H to 000007H),
User ID is read with A
3
= 1 (Address range = 000008H to 000087H).
Lock Status is read with A
7
-A
0
= 0000FFH. Unlocked: DQ
3
= 1 / Locked: DQ
3
=0.
6. Valid Word-Addresses for Sec ID are from 000000H-000007H and 000008H to 000087H.
7. The device does not remain in Software Product ID Mode if powered down.
8. For Manufacture ID
With A
MS
-A
0
=0;Microchip Manufacturer ID = 00BFH is read
For Device ID -
Device ID can be read either in one cycle (address 01H) or in three cycles (addresses 01H, 0EH and 0FH)
One-cycle method -
With A
MS
-A
1
=0, A
0
=1; Microchip39VF3201C/3202C Device ID = 235F/235E is read
Three-cycle method -
With A
MS
-A
1
=0, A
0
=1; SST39VF3201C/3202C Device ID = 235F/235E is read (cycle 1)
With A
MS
-A
4
=0; A
3
-A
1
=1; A
0
=0; SST39VF3201C/3202C Device ID additional info = 1A/1A is read (Note: 1A = 32 Mbit)
(cycle 2)
With A
MS
-A
4
=0; A
3
-A
0
=1; SST39VF3201C/3202C Device ID additional info = 00/01 is read (00/01 = Bottom/Top Boot)
(cycle 3)
A
MS
= Most significant address
A
MS
=A
20
for SST39VF3201C/3202C
9. Both Software ID Exit operations are equivalent
10. If users never lock after programming, Sec ID can be programmed over the previously unprogrammed bits (data=1)
using the Sec ID mode again (the programmed “0” bits cannot be reversed to “1”). Valid Word-Addresses for Sec ID are
from 000000H-000007H and 000008H to 000087H.
Table 8: CFI Query Identification String
1
for SST39VF3201C/3202C
1. Refer to CFI publication 100 for more details.
Address Data Data
10H 0051H Query Unique ASCII string “QRY”
11H 0052H
12H 0059H
13H 0002H Primary OEM command set
14H 0000H
15H 0000H Address for Primary Extended Table
16H 0000H
17H 0000H Alternate OEM command set (00H = none exists)
18H 0000H
19H 0000H Address for Alternate OEM extended Table (00H = none exits)
1AH 0000H
T8.0 20005020

SST39VF3201C-70-4I-B3KE

Mfr. #:
Manufacturer:
Microchip Technology
Description:
NOR Flash 2.7V to 3.6V 32Mbit Multi-Prps Fl
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: