MAX16047/MAX16049
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
22 ______________________________________________________________________________________
Any_Fault Outputs
GPIO1–GPIO4 are configurable as active-low push-pull
or open-drain fault-dependent outputs. These outputs
assert when any monitored input exceeds an overvolt-
age, undervoltage, or early warning threshold.
FAULT1 and FAULT2
GPIO5 and GPIO6 are configurable as dedicated fault
outputs, FAULT1 and FAULT2, respectively. Fault
outputs can assert on one or more overvoltage, under-
voltage, or early warning conditions for selected inputs.
FAULT1 and FAULT2 dependencies are set using reg-
isters r15h to r18h. See Table 7.
If a fault output depends on more than one MON_, the
fault output will assert if one or more MON_ exceeds a
programmed threshold voltage.
Table 7. FAULT1 and FAULT2 Output Configuration and Dependencies
REGISTER/
EEPROM
ADDRESS
BIT RANGE DESCRIPTION
[0] 1 = FAULT1 is a digital output dependent on MON1
[1] 1 = FAULT1 is a digital output dependent on MON2
[2] 1 = FAULT1 is a digital output dependent on MON3
[3] 1 = FAULT1 is a digital output dependent on MON4
[4] 1 = FAULT1 is a digital output dependent on MON5
[5] 1 = FAULT1 is a digital output dependent on MON6
[6] 1 = FAULT1 is a digital output dependent on MON7
15h
[7] 1 = FAULT1 is a digital output dependent on MON8
[0] 1 = FAULT1 is a digital output dependent on MON9*
[1] 1 = FAULT1 is a digital output dependent on MON10*
[2] 1 = FAULT1 is a digital output dependent on MON11*
[3] 1 = FAULT1 is a digital output dependent on MON12*
[4]
1 = FAULT1 is a digital output that depends on the overvoltage thresholds at the input
selected by r15h and r16h[3:0]
[5]
1 = FAULT1 is a digital output that depends on the undervoltage thresholds at the
input selected by r15h and r16h[3:0]
[6]
1 = FAULT1 is a digital output that depends on the early warning thresholds at the
input selected by r15h and r16h[3:0]
16h
[7]
0 = FAULT1 is an active-low digital output
1 = FAULT1 is an active-high digital output
[0] 1 = FAULT2 is a digital output dependent on MON1
[1] 1 = FAULT2 is a digital output dependent on MON2
[2] 1 = FAULT2 is a digital output dependent on MON3
[3] 1 = FAULT2 is a digital output dependent on MON4
[4] 1 = FAULT2 is a digital output dependent on MON5
[5] 1 = FAULT2 is a digital output dependent on MON6
[6] 1 = FAULT2 is a digital output dependent on MON7
17h
[7] 1 = FAULT2 is a digital output dependent on MON8
MAX16047/MAX16049
Fault-On Power-Up (FAULTPU)
GPIO6 indicates a fault during power-up or power-
down when configured as a “fault-on power-up” output.
Under these conditions, all EN_OUT_ voltages are
pulled low and fault data is saved to nonvolatile
EEPROM. See the
Faults
section.
MARGIN
GPIO6 is configurable as an active-low MARGIN input.
Drive MARGIN low before varying system voltages above
or below the thresholds to avoid signaling an error. Drive
MARGIN high for normal operation.
When MARGIN is pulled low or r4Dh[1] is a ‘1,’ the mar-
gin function is enabled. FAULT1, FAULT2, Any_Fault,
and RESET are latched in their current state. Threshold
violations will be ignored, and faults will not be logged.
Manual Reset (MR)
GPIO4 is configurable to act as an active-low manual
reset input, MR. Drive MR low to assert RESET. RESET
remains low for the selected reset timeout period after
MR transitions from low to high. See the
RESET
section
for more information on selecting a reset timeout period.
Watchdog Input (WDI) and Output (WDO)
Set r1Eh[1:0] and r1Dh[7] to ‘110’ to configure GPIO6 as
WDO. Set r1Dh[6:4] to ‘111’ to configure GPIO5 as WDI.
WDO is an open-drain active-low output. See the
Watchdog Timer
section for more information about the
operation of the watchdog timer.
Programmable Outputs
(EN_OUT1–EN_OUT12)
The MAX16047 includes twelve programmable outputs,
and the MAX16049 includes eight programmable out-
puts. These outputs are capable of connecting to either
the enable (EN) inputs of a DC-DC or LDO power supply
or to the gates of series-pass MOSFETs for closed-loop
tracking mode, or for charge-pump mode. Selectable
output configurations include: active-low or active-high,
open-drain or push-pull. EN_OUT1–EN_OUT4 are also
configurable for closed-loop tracking, and EN_OUT1–
EN_OUT6 can act as charge-pump outputs with no
closed-loop tracking. Use the registers r1Fh to r22h to
configure outputs. See Table 8 for detailed information
on configuring EN_OUT1–EN_OUT12.
Table 7. FAULT1 and FAULT2 Output Configuration and Dependencies (continued)
REGISTER/
EEPROM
ADDRESS
BIT RANGE DESCRIPTION
[0] 1 = FAULT2 is a digital output dependent on MON9*
[1] 1 = FAULT2 is a digital output dependent on MON10*
[2] 1 = FAULT2 is a digital output dependent on MON11*
[3] 1 = FAULT2 is a digital output dependent on MON12*
[4]
1 = FAULT2 is a digital output that depends on the overvoltage thresholds at the input
selected by r17h and r18h[3:0]
[5]
1 = FAULT2 is a digital output that depends on the undervoltage thresholds at the
input selected by r17h and 18h[3:0]
[6]
1 = FAULT2 is a digital output that depends on the early warning thresholds at the
input selected by r17h and r18h[3:0]
18h
[7]
0 = FAULT2 is an active-low digital output
1 = FAULT2 is an active-high digital output
*
MAX16047 only
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
______________________________________________________________________________________ 23
MAX16047/MAX16049
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
24 ______________________________________________________________________________________
Table 8. EN_OUT1–EN_OUT12 Configuration
REGISTER/
EEPROM
ADDRESS
BIT RANGE DESCRIPTION
[2:0]
EN_OUT1 Configuration:
000 = EN_OUT1 is an open-drain active-low output
001 = EN_OUT1 is an open-drain active-high output
010 = EN_OUT1 is a push-pull active-low output
011 = EN_OUT1 is a push-pull active-high output
100 = EN_OUT1 is used in closed-loop tracking
101 = EN_OUT1 is configured with a charge-pump output (MON1 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
[5:3]
EN_OUT2 Configuration:
000 = EN_OUT2 is an open-drain active-low output
001 = EN_OUT2 is an open-drain active-high output
010 = EN_OUT2 is a push-pull active-low output
011 = EN_OUT2 is a push-pull active-high output
100 = EN_OUT2 is used in closed-loop tracking
101 = EN_OUT2 is configured with a charge-pump output (MON2 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
1Fh
[7:6]
EN_OUT3 Configuration (LSBs):
000 = EN_OUT3 is an open-drain active-low output
001 = EN_OUT3 is an open-drain active-high output
010 = EN_OUT3 is a push-pull active-low output
011 = EN_OUT3 is a push-pull active-high output
100 = EN_OUT3 is used in closed-loop tracking
101 = EN_OUT3 is configured with a charge-pump output (MON3 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved