MAX16047/MAX16049
Table 8. EN_OUT1–EN_OUT12 Configuration (continued)
REGISTER/
EEPROM
ADDRESS
BIT RANGE DESCRIPTION
[0] EN_OUT3 Configuration (MSB)—see r1Fh[7:6]
[3:1]
EN_OUT4 Configuration:
000 = EN_OUT4 is an open-drain active-low output
001 = EN_OUT4 is an open-drain active-high output
010 = EN_OUT4 is a push-pull active-low output
011 = EN_OUT4 is a push-pull active-high output
100 = EN_OUT4 is used in closed-loop tracking
101 = EN_OUT4 is configured with a charge-pump output (MON4 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
[6:4]
EN_OUT5 Configuration:
000 = EN_OUT5 is an open-drain active-low output
001 = EN_OUT5 is an open-drain active-high output
010 = EN_OUT5 is a push-pull active low output
011 = EN_OUT5 is a push-pull active-high output
100 = Reserved. EN_OUT5 is not usable for closed-loop tracking.
101 = EN_OUT5 is configured with a charge-pump output (MON5 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
20h
[7] EN_OUT6 Configuration (LSB)—see r21h[1:0]
[1:0]
EN_OUT6 Configuration (MSBs):
000 = EN_OUT6 is an open-drain active-low output
001 = EN_OUT6 is an open-drain active-high output
010 = EN_OUT6 is a push-pull active-low output
011 = EN_OUT6 is a push-pull active-high output
100 = Reserved. EN_OUT6 is not useable for closed-loop tracking.
101 = EN_OUT6 is configured with a charge-pump output (MON6 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
[3:2]
EN_OUT7 Configuration:
00 = EN_OUT7 is an open-drain active-low output
01 = EN_OUT7 is an open-drain active-high output
10 = EN_OUT7 is a push-pull active-low output
11 = EN_OUT7 is a push-pull active-high output
[5:4]
EN_OUT8 Configuration:
00 = EN_OUT8 is an open-drain active-low output
01 = EN_OUT8 is an open-drain active-high output
10 = EN_OUT8 is a push-pull active-low output
11 = EN_OUT8 is a push-pull active-high output
21h
[7:6]
EN_OUT9 Configuration*:
00 = EN_OUT9 is an open-drain active-low output
01 = EN_OUT9 is an open-drain active-high output
10 = EN_OUT9 is a push-pull active-low output
11 = EN_OUT9 is a push-pull active-high output
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
______________________________________________________________________________________ 25
MAX16047/MAX16049
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
26 ______________________________________________________________________________________
Table 8. EN_OUT1–EN_OUT12 Configuration (continued)
REGISTER/
EEPROM
ADDRESS
BIT RANGE DESCRIPTION
[1:0]
EN_OUT10 Configuration*:
00 = EN_OUT10 is an open-drain active-low output
01 = EN_OUT10 is an open-drain active-high output
10 = EN_OUT10 is a push-pull active-low output
11 = EN_OUT10 is a push-pull active-high output
[3:2]
EN_OUT11 Configuration*:
00 = EN_OUT11 is an open-drain active-low output
01 = EN_OUT11 is an open-drain active-high output
10 = EN_OUT11 is a push-pull active-low output
11 = EN_OUT11 is a push-pull active-high output
[5:4]
EN_OUT12 Configuration*:
00 = EN_OUT12 is an open-drain active-low output
01 = EN_OUT12 is an open-drain active high output
10 = EN_OUT12 is a push-pull active-low output
11 = EN_OUT12 is a push-pull active-high output
22h
[7:6] Reserved
*
MAX16047 only
Charge-Pump Configuration
EN_OUT1–EN_OUT6 can act as high-voltage charge-
pump outputs to drive up to six external n-channel
MOSFETs. During sequencing, an EN_OUT_ output
configured this way drives 6µA until the voltage reach-
es 5V above the corresponding MON_ to fully enhance
the external n-channel MOSFET. For example,
EN_OUT2 will rise to 5V above MON2. See the
Sequencing
section for more detailed information on
power-supply sequencing.
Closed-Loop Tracking Operation
EN_OUT1–EN_OUT4 can operate in closed-loop track-
ing mode. When configured for closed-loop tracking,
EN_OUT1–EN_OUT4 are capable of driving the gates
of up to four external n-channel MOSFETs. For closed-
loop tracking, configure GPIO1–GPIO4 as return-sense
line inputs (INS_) to be used in conjunction with
EN_OUT1–EN_OUT4 and MON1–MON4. See the
Closed-Loop Tracking
section.
Open-Drain Output Configuration
Connect an external pullup resistor from the output to
an external voltage up to 6V (abs max, EN_OUT7–
EN_OUT12) or 12V (abs max, EN_OUT1–EN_OUT6)
when configured as an open-drain output. Choose the
pullup resistor depending on the number of devices
connected to the open-drain output and the allowable
current consumption. The open-drain output configura-
tion allows wire-ORed connection.
Push-Pull Output Configuration
The MAX16047/MAX16049s’ programmable outputs
sink 2mA and source 100µA when configured as push-
pull outputs.
EN_OUT_ State During Power-Up
When V
CC
is ramped from 0V to the operating supply
voltage, the EN_OUT_ output is high impedance until
V
CC
is approximately 2.4V and then EN_OUT_ will be in
its configured deasserted state. See Figures 3 and 4.
RESET is configured as an active-low open-drain out-
put pulled up to V
CC
through a 10kΩ resistor for
Figures 3 and 4.
MAX16047/MAX16049
MAX16047 fig03
20ms/div
V
CC
2V/div
EN_OUT_
2V/div
0V
RESET
2V/div
0V
0V
Figure 3. RESET and EN_OUT_ During Power-Up, EN_OUT_ Is
in Open-Drain Active-Low Configuration
MAX16047 fig04
10ms/div
V
CC
2V/div
EN_OUT_
2V/div
0V
RESET
2V/div
0V
0V
HIGH-Z
ASSERTED
LOW
UVLO
Figure 4. RESET and EN_OUT_ During Power-Up, EN_OUT_ Is
in Push-Pull Active-High Configuration
Sequencing
Each EN_OUT_ has one or more associated MON_
inputs, facilitating the voltage monitoring of multiple
power supplies. To sequence a system of power sup-
plies safely, the output voltage of a power supply must
be good before the next power supply may turn on.
Connect EN_OUT_ outputs to the enable input of an
external power supply and connect MON_ inputs to the
output of the power supply for voltage monitoring. More
than one MON_ may be used if the power supply has
multiple outputs.
Sequence Order
The MAX16047/MAX16049 utilize a system of ordered
slots to sequence multiple power supplies. To deter-
mine the sequence order, assign each EN_OUT_ to a
slot ranging from Slot 0 to Slot 11. EN_OUT_(s)
assigned to Slot 0 are turned on first, followed by out-
puts assigned to Slot 1, and so on through Slot 11.
Multiple EN_OUT_s assigned to the same slot turn on at
the same time.
Each slot has a built-in configurable sequence delay
(registers r50h to r54h) ranging from 20µs to 1.6s. During
a reverse sequence, slots are turned off in reverse order
starting from Slot 11. The MAX16047/MAX16049 may be
configured to power-down in simultaneous mode or in
reverse sequence mode as set in r54h[4]. See Tables 9,
10, and 11 for the EN_OUT_ slot assignment bits, and
Tables 12 and 13 for the sequence delays.
Monitoring Inputs While Sequencing
An enabled MON_ input may be assigned to a slot rang-
ing from Slot 1 to Slot 12. Monitoring inputs are always
checked at the beginning of a slot. The inputs are given
the power-up fault delay within which they must satisfy
the programmed undervoltage limit; otherwise a fault
condition will occur. The fault occurs regardless of the
critical fault enable bits. This undervoltage limit cannot
be disabled during power-up and power-down.
EN_OUT_s configured for open-drain, push-pull, or
charge-pump operation are always asserted at the end
of a slot, following the sequence delay. See Tables 9,
10, and 11 for the MON_ slot assignment bits.
Slot 0 does not monitor any MON_ input. Instead, Slot 0
waits for the Software Enable bit r4Dh[0] to be a logic ‘0’
and for the voltage on EN to rise above 0.525V before
asserting any assigned outputs. Outputs assigned to
Slot 0 are asserted before the Slot 0 sequence delay.
Generally, Slot 0 controls the enable inputs of power
supplies that are first in the sequence.
Similarly, Slot 12 does not control any EN_OUT_ out-
puts. Rather, Slot 12 monitors assigned MON_ inputs
and then enters the power-on state. Generally, Slot 12
monitors the last power supplies in the sequence. The
power-up sequence is complete when any MON_ inputs
assigned to Slot 12 exceed their undervoltage thresh-
olds and the sequence delay is expired. If no MON_
inputs are assigned to Slot 12, the power-up sequence
is complete after the slot sequence delay is expired.
The output rail(s) of a power supply should be moni-
tored by one or more MON_ inputs placed in the suc-
ceeding slot, ensuring that the output of the supply is
not checked until it has first been turned on. For exam-
ple, if a power supply uses EN_OUT1 located in Slot 3
and has two monitoring inputs, MON1 and MON2, they
must both be assigned to Slot 4. In this example,
EN_OUT1 turns on at the end of Slot 3. At the start of
Slot 4, MON1 and MON2 must exceed the undervolt-
age threshold before the programmed power-up fault
delay; otherwise a fault triggers.
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
______________________________________________________________________________________ 27

MAX16047ETN+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Supervisory Circuits 12Ch EEPROM Prob System Manage
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet