ZL30409 Data Sheet
21
Zarlink Semiconductor Inc.
† See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - Performance
Characteristics Sym. Min. Max. Units
Conditions/
Notes†
1 Freerun Mode accuracy with OSCi at: ±0 ppm -0 +0 ppm 5-9
2 ±32 ppm -32 +32 ppm 5-9
3 ±100 ppm -100 +100 ppm 5-9
4 Holdover Mode accuracy with OSCi at: ± 0 ppm -0.05 +0.05 ppm 1,2,4,6-9,41
5 ±32 ppm -0.05 +0.05 ppm 1,2,4,6-9,41
6 ±100 ppm -0.05 +0.05 ppm 1,2,4,6-9,41
7 Capture range with OSCi at: ±0 ppm -230 +230 ppm 1-3,6-9
8 ±32 ppm -198 +198 ppm 1-3,6-9
9 ±100 ppm -130 +130 ppm 1-3,6-9
10 Phase lock time 30 s 1-3,6-15
11 Output phase continuity with: reference switch 200 ns 1-3,6-15
12 mode switch to Normal 200 ns 1-2,4-15
13 mode switch to Freerun 200 ns 1-,4,6-15
14 mode switch to Holdover 50 ns 1-3,6-15
15 MTIE (maximum time interval error) 600 ns 1-15,28
16 Reference input for Auto-Holdover with:
8 kHz or 19.44 MHz
-30k +30k ppm
1-3,6,9,10-12
17 1.544 MHz -30k +30k ppm 1-3,7,10-12
18 2.048 MHz -30k +30k ppm 1-3,8,10-12