ZL30409 Data Sheet
28
Zarlink Semiconductor Inc.
† See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - 2.048 MHz Input to 2.048 MHz Output Jitter Transfer
Characteristics Sym. Min. Max. Units Conditions/Notes
1 Jitter at output for 1 Hz@3.00 UIpp input
with 40 Hz to 100 kHz filter
2.9 UIpp 1-3,8,10 -15,
22-23,25,31,37
2 0.09 UIpp 1-3,8,10 -15,
22-23,25,31,38
3 Jitter at output for 3 Hz@2.33 UIpp input
with 40 Hz to 100 kHz filter
1.3 UIpp 1-3,8,10 -15,
22-23,25,31,37
4 0.10 UIpp 1-3,8,10 -15,
22-23,25,31,38
5 Jitter at output for 5 Hz@2.07 UIpp input
with 40 Hz to 100 kHz filter
0.80 UIpp 1-3,8,10-15,
22-23,25,31,37
6 0.10 UIpp 1-3,8,10-15,
22-23,25,31,38
7 Jitter at output for 10 Hz@1.76 UIpp input
with 40 Hz to 100 kHz filter
0.40 UIpp 1-3,8,10-15,
22-23,25,31,37
8 0.10 UIpp 1-3,8,10-15,
22-23,25,31,38
9 Jitter at output for 100 Hz@1.50 UIpp input
with 40 Hz to 100 kHz filter
0.06 UIpp 1-3,8,10-15,
22-23,25,31,37
10 0.05 UIpp 1-3,8,10-15,
22-23,25,31,38
11 Jitter at output for 2400 Hz@1.50 UIpp input
with 40 Hz to 100 kHz filter
0.04 UIpp 1-3,8,10-15,
22-23,25,31,37
12 0.03 UIpp 1-3,8,10-15,
22-23,25,31,38
13 Jitter at output for 100kHz@0.20UIpp input
with 40 Hz to 100 kHz filter
0.04 UIpp 1-3,8,10-15,
22-23,25,31,37
14 0.02 UIpp 1-3,8,10-15,
22-23,25,31,36
ZL30409 Data Sheet
29
Zarlink Semiconductor Inc.
† See "Notes" following AC Electrical Characteristics tables.
† See "Notes" following AC Electrical Characteristics tables.
† See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - 8 kHz Input Jitter Tolerance
Characteristics Sym. Min. Max. Units Conditions/Notes
1 Jitter tolerance for 1 Hz input 0.80 UIpp 1-3,6,10 -15,22-23,25-27,29
2 Jitter tolerance for 5 Hz input 0.70 UIpp 1-3,6,10 -15,22-23,25-27,29
3 Jitter tolerance for 20 Hz input 0.60 UIpp 1-3,6,10 -15,22-23,25-27,29
4 Jitter tolerance for 300 Hz input 0.20 UIpp 1-3,6,10 -15,22-23,25-27,29
5 Jitter tolerance for 400 Hz input 0.15 UIpp 1-3,6,10 -15,22-23,25-27,29
6 Jitter tolerance for 700 Hz input 0.08 UIpp 1-3,6,10 -15,22-23,25-27,29
7 Jitter tolerance for 2400 Hz input 0.02 UIpp 1-3,6,10 -15,22-23,25-27,29
8 Jitter tolerance for 3600 Hz input 0.01 UIpp 1-3,6,10 -15,22-23,25-27,29
AC Electrical Characteristics - 1.544 MHz Input Jitter Tolerance
Characteristics Sym. Min. Max. Units Conditions/Notes
1 Jitter tolerance for 1 Hz input 150 UIpp 1-3,7,10 -15,22-23,25-27,30
2 Jitter tolerance for 5 Hz input 140 UIpp 1-3,7,10 -15,22-23,25-27,30
3 Jitter tolerance for 20 Hz input 130 UIpp 1-3,7,10 -15,22-23,25-27,30
4 Jitter tolerance for 300 Hz input 35 UIpp 1-3,7,10 -15,22-23,25-27,30
5 Jitter tolerance for 400 Hz input 25 UIpp 1-3,7,10 -15,22-23,25-27,30
6 Jitter tolerance for 700 Hz input 15 UIpp 1-3,7,10 -15,22-23,25-27,30
7 Jitter tolerance for 2400 Hz input 4 UIpp 1-3,7,10 -15,22-23,25-27,30
8 Jitter tolerance for 10 kHz input 1 UIpp 1-3,7,10 -15,22-23,25-27,30
9 Jitter tolerance for 100 kHz input 0.5 UIpp 1-3,7,10 -15,22-23,25-27,30
AC Electrical Characteristics - 2.048 MHz Input Jitter Tolerance
Characteristics Sym. Min. Max. Units Conditions/Notes
1 Jitter tolerance for 1 Hz input 150 UIpp 1-3,8,10 -15,22-23,25-27,31
2 Jitter tolerance for 5 Hz input 140 UIpp 1-3,8,10 -15,22-23,25-27,31
3 Jitter tolerance for 20 Hz input 130 UIpp 1-3,8,10 -15,22-23,25-27,31
4 Jitter tolerance for 300 Hz input 50 UIpp 1-3,8,10 -15,22-23,25-27,31
5 Jitter tolerance for 400 Hz input 40 UIpp 1-3,8,10 -15,22-23,25-27,31
6 Jitter tolerance for 700 Hz input 20 UIpp 1-3,8,10 -15,22-23,25-27,31
7 Jitter tolerance for 2400 Hz input 5 UIpp 1-3,8,10 -15,22-23,25-27,31
8 Jitter tolerance for 10 kHz input 1 UIpp 1-3,8,10 -15,22-23,25-27,31
9 Jitter tolerance for 100 kHz input 1 UIpp 1-3,8,10 -15,22-23,25-27,31
ZL30409 Data Sheet
30
Zarlink Semiconductor Inc.
† See "Notes" following AC Electrical Characteristics tables.
† Notes:
Voltages are with respect to ground (GND) unless otherwise stated.
Supply voltage and operating temperature are as per Recommended Operating Conditions.
Timing parameters are as per AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels
1. PRI reference input selected.
2. SEC reference input selected.
3. Normal Mode selected.
4. Holdover Mode selected.
5. Freerun Mode selected.
6. 8 kHz Frequency Mode selected.
7. 1.544 MHz Frequency Mode selected.
8. 2.048 MHz Frequency Mode selected.
9. 19.44 MHz Frequency Mode selected.
10. Master clock input OSCi at 20 MHz
±0 ppm.
11. Master clock input OSCi at 20 MHz
±32 ppm.
12. Master clock input OSCi at 20 MHz ±100 ppm.
13. Selected reference input at
±0 ppm.
14. Selected reference input at
±32 ppm.
15. Selected reference input at ±100 ppm.
16. For Freerun Mode of
±0ppm.
17. For Freerun Mode of
±32 ppm.
18. For Freerun Mode of ±100 ppm.
19. For capture range of
±230 ppm.
20. For capture range of
±198 ppm.
21. For capture range of ±130 ppm.
22. 25 pF capacitive load.
23. OSCi Master Clock jitter is less than 2 nspp, or 0.04 UIpp where1 UIpp=1/20 MHz.
24. Jitter on reference input is less than 7 nspp.
25. Applied jitter is sinusoidal.
26. Minimum applied input jitter magnitude to regain synchronization.
27. Loss of synchronization is obtained at slightly higher input jitter amplitudes.
28. Within 10 ms of the state, reference or input change.
29. 1 UIpp = 125 us for 8 kHz signals.
30. 1 UIpp = 648 ns for 1.544 MHz signals.
31. 1 UIpp = 488 ns for 2.048 MHz signals.
32. 1 UIpp = 323 ns for 3.088 MHz signals.
33. 1 UIpp = 244 ns for 4.096 MHz signals.
34. 1 UIpp = 122 ns for 8.192 MHz signals.
35. 1 UIpp = 61 ns for 16.384 MHz signals.
36. 1 UIpp = 51.44 ns for 19.44 MHz signals.
37. No filter.
38. 40 Hz to 100 kHz bandpass filter.
39. With respect to reference input signal frequency.
40. After a RST
or TCLR.
41. Master clock duty cycle 40% to 60%.
42. Prior to Holdover Mode, device was in Normal Mode and phase locked.
AC Electrical Characteristics - OSCi 20 MHz Master Clock Input
Characteristics Sym. Min. Max. Units Conditions/Notes
1 Tolerance -0 +0 ppm 16,19
2 -32 +32 ppm 17,20
3 -100 +100 ppm 18,21
4 Duty cycle 40 60 %
5 Rise time 10 ns
6 Fall time 10 ns

ZL30409DDF1

Mfr. #:
Manufacturer:
Microchip / Microsemi
Description:
Phase Locked Loops - PLL Pb Free T1/E1 SYS.SYNC+STRATUM 3 H/OVER
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet