Integrated Silicon Solution, Inc. — www.issi.com —
1-800-379-4774
25
Rev. 00D
06/02/08
IS42S32200E
CLK
CKE
HIGH - Z
COLUMN ADDRESS
AUTO PRECHARGE
BANK ADDRESS
CS
RAS
CAS
WE
A0-A7
A10
BA0, BA1
NO PRECHARGE
A8, A9
WRITE Command
The starting column and bank addresses are provided with
the WRITE command, and auto precharge is either enabled
or disabled for that access. If auto precharge is enabled, the
row being accessed is precharged at the completion of the
burst. For the generic WRITE commands used in the
following illustrations, auto precharge is disabled.
During WRITE bursts, the first valid
data-in
element will be
registered coincident
with the
WRITE
command.
Subsequent
data elements will be registered on each successive
positive clock edge. Upon completion of a fixed-length
burst, assuming no other commands have been initiated,
the DQs will remain High-Z and any additional input data will
be ignored (see WRITE Burst). A full-page burst will
continue until terminated. (At the end of the page, it will wrap
to column 0 and continue.)
Data for any WRITE burst may be truncated with a
subsequent WRITE command, and data for a fixed-length
WRITE burst may be immediately followed by data for a
WRITE command. The new WRITE command can be issued
on any clock following the previous WRITE command, and
the data provided coincident with the new command applies
to the new command.
An example is shown in WRITE to WRITE diagram. Data
n
+ 1 is either the last of a burst of two or the last desired
of a longer burst. The 64Mb SDRAM uses a pipelined
architecture and therefore does not require the
2n
rule
associated with a prefetch architecture. A WRITE command
can be initiated on any clock cycle following a previous
WRITE command. Full-speed random write accesses
within a page can be performed to the same bank, as
shown in Random WRITE Cycles, or each subsequent
WRITE may be performed to a different bank.
Data for any WRITE burst may be truncated with a
subsequent READ command, and data for a fixed-length
WRITE burst may be immediately followed by a subsequent
READ command. Once the READ com mand is regis-
tered, the data inputs will be ignored, and WRITEs will not
be executed. An example is shown in WRITE to READ.
Data
n
+ 1 is either the last of a burst of two or the last
desired of a longer burst.
Data for a fixed-length WRITE burst may be fol lowed by,
or truncated with, a PRECHARGE command to the same
bank (provided that auto precharge was not activated),
and a full-page WRITE burst may be truncated with a
PRECHARGE command to the same bank. The
PRECHARGE command should be issued tWR after the
clock edge at which the last desired input data element is
registered. The auto precharge mode requires a tWR of at
least one clock plus time, regardless of frequency. In
addition, when truncating a WRITE burst, the DQM signal
must be used to mask input data for the clock edge prior
to, and the clock edge coincident with, the PRECHARGE
command. An example is shown in the WRITE to
PRECHARGE diagram. Data
n
+1 is either the last of a burst
of two or the last desired of a longer burst. Following the
PRECHARGE command, a subsequent command to the
same bank cannot be issued until tRP is met.
In the case of a fixed-length burst being executed to
completion, a PRECHARGE command issued at the opti-
mum time
(as described above)
provides the same operation
that would result from the same fixed-length burst with auto
precharge. The disadvantage of the
PRECHARGE
command
is that it requires that the command and address buses be
available at the appropriate time to issue the command; the
advantage of the PRECHARGE command is that it can be
used to truncate fixed-length or full-page bursts.
Fixed-length or full-page WRITE bursts can be truncated
with the BURST TERMINATE command. When truncating
a WRITE burst, the input data applied coincident with the
BURST TERMINATE command will be ignored. The last
data written (provided that DQM is LOW at that time) will
be the input data applied one clock previous to the BURST
TERMINATE command. This is shown in WRITE Burst
Termination, where data
n
is the last desired data element
of a longer burst.
WRITEs
WRITE bursts are initiated with a WRITE command, as
shown in WRITE Command diagram.
26
Integrated Silicon Solution, Inc. — www.issi.com —
1-800-379-4774
Rev. 00D
06/02/08
IS42S32200E
CLK
COMMAND
ADDRESS
DQ
T0 T1 T2 T3
WRITE
NOP
NOP
NOP
DIN n
DIN n+1
BANK,
COL n
DON'T CARE
CLK
COMMAND
ADDRESS
DQ
T0 T1 T2
WRITE
NOP
WRITE
DIN n
DIN n+1
DIN b
BANK,
COL n
BANK,
COL b
DON'T CARE
WRITE Burst
WRITE to WRITE
CLK
COMMAND
ADDRESS
DQ
T0 T1 T2 T3
WRITE
WRITE
WRITE
WRITE
DIN n
DIN b
DIN m
DIN x
BANK,
COL n
BANK,
COL b
BANK,
COL m
BANK,
COL x
Random WRITE Cycles
Burst length = 2 DQM ix low.
DQMx is low. Each Write Command
may be to any bank.
DQMx is low. Each Write Command
may be to any bank.
Integrated Silicon Solution, Inc. — www.issi.com —
1-800-379-4774
27
Rev. 00D
06/02/08
IS42S32200E
DON'T CARE
CLK
DQM
COMMAND
ADDRESS
DQ
T0 T1 T2 T3 T4 T5 T6
WRITE
NOP NOP NOP ACTIVE NOP
BANK a,
COL n
BANK a,
ROW
BANK
(a or all)
tWR
tRP
PRECHARGE
DIN n
DIN n+1
WRITE to PRECHARGE (tWR = 1 CLK (tCK tWR)
DON'T CARE
CLK
COMMAND
ADDRESS
DQ
T0 T1 T2 T3 T4 T5
WRITE
NOP
READ
NOP
NOP NOP
DIN n
DIN n+1
DOUT b
DOUT b+1
BANK,
COL n
BANK,
COL b
WRITE to READ

IS42S32200E-6BI-TR

Mfr. #:
Manufacturer:
Description:
DRAM 64M (2Mx32) 166MHz SDRAM, 3.3v