Energy Metering IC with Autocalibration
Data Sheet
ADE9153A
Rev. 0
Document Feedbac
k
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700 ©2018 Analog Devices, Inc. All rights reserved.
Technical Suppor t www.analog.com
FEATURES
mSure autocalibration
Automatic calibration based on a direct measurement of
the full signal path
Calibration procedure not requiring a reference meter
mSure autocalibration Class 1 meter guaranteed
3 high performance ADCs
88 dB SNR
High gain current channel: ±26.04 mV peak, 18.4 mV rms
input at highest gain setting
Advanced metrology feature set
WATT, VAR, VA, Wh, VARh, and VAh
Supports active energy standards: IEC 62053-21;
IEC 62053-22; EN50470-3; OIML R46; and ANSI C12.20
Supports reactive energy standards: IEC 62053-23 and
IEC 62053-24
Current and voltage rms measurement
Power quality measurements
Operating temperature, industrial range: −40°C to +85°C
APPLICATIONS
Single-phase energy meters
Energy and power measurement
Street lighting
Smart power distribution system
Machine health
GENERAL DESCRIPTION
The ADE9153A
1
is a highly accurate, single-phase, energy metering
IC with autocalibration. The mSur autocalibration feature allows
a meter to automatically calibrate the current and voltage channels
without using an accurate source or an accurate reference meter
when a shunt resistor is used as a current sensor. Class 1 and
Class 2 meters are supported by mSure autocalibration.
The ADE9153A incorporates three high performance analog-
to-digital converters (ADCs), providing an 88 dB signal-to-noise
ratio (SNR). The ADE9153A offers an advanced metrology feature
set of measurements like line voltage and current, active energy,
fundamental reactive energy, and apparent energy calculations,
and current and voltage rms calculations. ADE9153A includes
power quality measurements such as zero crossing detection, line
period calculation, angle measurement, dip and swell, peak and
overcurrent detection, and power factor measurements. Each input
channel supports independent and flexible gain stages. Current
Channel A is ideal for shunts, having a flexible gain stage and
providing full-scale input ranges from 62.5 mV peak down to
26.04 mV peak. Current Channel B has gain stages of 1×, 2×,
and 4× for use with current transformers (CTs). A high speed,
10 MHz, serial peripheral interface (SPI) port allows access to
the ADE9153A registers.
Note that throughout this data sheet, multifunction pins, such
as ZX/DREADY/CF2, are referred to either by the entire pin
name or by a single function of the pin, for example, CF2, when
only that function is relevant.
The ADE9153A operates from a 3.3 V supply and is available in
a 32-lead LFCSP package.
TYPICAL APPLICATIONS CIRCUIT
mSure VOLTAGE DRIVER
DIGITAL SIGNAL
PROCESSING
SINC AND
DECIMATION
METROLOGY ENGINE
WATT, VA, VAR,
WATT-HR, VA-HR,
VAR-HR, IRMS, VRMS
mSure DETECTOR
SAR
TEMPERATURE
SENSOR
CLOCK
GENERATION
CF
GENERATION
ZERO
CROSSING
SPI
INTERFACE
CLKIN
CLKOUT
CF1
ZX/DREADY/CF2
SCLK
MISO/TX
MOSI/RX
SS
AGND/DGND
VAMS
VAN
VAP
AGND/DGND
IAN
IAP
IAMS
IBMS
IBP
IBN
AGND/DGND
B
R
SHUNT
R
BIG
R
SMALL
PHASENEUTRAL
IRQ
ADC
ADC
PGA
mSure
CURRENT DRIVER
ADCPGA
ADE9153A
LOAD
16519-001
Figure 1.
1
Protected by U.S. Patents 8,350,558; 8,010,304; WO2013038176 A3; 0113507 A1; 0253102 A1; 0354266 A1; and 0154029 A1.
ADE9153A Data Sheet
Rev. 0 | Page 2 of 50
TABLE OF CONTENTS
Features .............................................................................................. 1
Applications ....................................................................................... 1
General Description ......................................................................... 1
Typical Applications Circuit ............................................................ 1
Revision History ............................................................................... 2
Specifications ..................................................................................... 3
Autocalibration ............................................................................. 6
SPI Timing Characteristics ......................................................... 7
Absolute Maximum Ratings ............................................................ 8
Thermal Resistance ...................................................................... 8
ESD Caution .................................................................................. 8
Pin Configuration and Function Descriptions ............................. 9
Typical Performance Characteristics ........................................... 11
Energy Linearity Over Supply and Temperature ................... 11
Energy Error Over Frequency and Power Factor................... 13
RMS Linearity Over Temperature and RMS Error Over
Frequency .................................................................................... 14
Signal-To-Noise Ratio (SNR) Performance Over Dynamic
Range ............................................................................................ 17
Test Circuit ...................................................................................... 18
Terminology .................................................................................... 19
Theory of Operation ...................................................................... 21
mSure Autocalibration Feature ................................................. 21
Measurements ............................................................................. 22
Power Quality Measurements ................................................... 26
Applications Information .............................................................. 29
Interrupts/Events ........................................................................ 29
IRQ
Pin Interrupts ...................................................................... 29
Servicing Interrupts ................................................................... 29
CF2/ZX/DREADY Event Pin ................................................... 29
Accessing On-Chip Data ............................................................... 30
SPI Protocol Overview .............................................................. 30
UART Interface ........................................................................... 30
Communication VerifIcation Registers ................................... 31
CRC of Configuration Registers............................................... 31
Configuration Lock .................................................................... 31
Register Information ...................................................................... 32
Register Summary ...................................................................... 32
Register Details ........................................................................... 36
Outline Dimensions ....................................................................... 50
Ordering Guide .......................................................................... 50
REVISION HISTORY
2/2018—Revision 0: Initial Version
Data Sheet ADE9153A
Rev. 0 | Page 3 of 50
SPECIFICATIONS
VDD = 2.97 V to 3.63 V, AGND = DGND = 0 V, on-chip reference, CLKIN = 12.288 MHz, T
MIN
to T
MAX
= −40°C to +85°C, and T
A
= 25°C
(typical), unless otherwise noted.
Table 1.
Parameter Min Typ Max Unit Test Conditions/Comments
ACCURACY (MEASUREMENT ERROR
PER PHASE)
Percentage of the typical value derived from comparing
the actual value with the typical-based expected values
when a 10:1 signal is applied
Total Active Energy 0.1 %
Over a dynamic range of 3000 to 1, 10 sec accumulation
programmable gain amplifier (PGA), AI_PGAGAIN = 16×
0.2 % AI_PGAGAIN = 38.4×
0.25 %
Over a dynamic range of 10,000 to 1, 30 sec
accumulation; AI_PGAGAIN = 16×
0.5 % AI_PGAGAIN = 38.4×
Fundamental Reactive Energy 0.1 %
Over a dynamic range of 3000 to 1, 10 sec accumulation;
AI_PGAGAIN = 16×
0.2 % AI_PGAGAIN = 38.4×
0.25 %
Over a dynamic range of 10,000 to 1, 30 sec
accumulation AI_PGAGAIN = 16×
0.5 % AI_PGAGAIN = 38.4×
Total Apparent Energy 0.1 %
Over a dynamic range of 1000 to 1, 1 sec accumulation;
AI_PGAGAIN = 16×
0.2 % AI_PGAGAIN = 38.4×
0.25 %
Over a dynamic range of 3000 to 1, 10 sec accumulation
AI_PGAGAIN = 16×
0.5 % AI_PGAGAIN = 38.4×
RMS Current (I
RMS
) and Apparent
Power (VA)
0.1 %
Over a dynamic range of 1000 to 1, 1 sec (averaging)
AI_PGAGAIN = 16×, BI_PGAGAIN = 1×
0.2 %
Over a dynamic range of 1000 to 1, 1 sec (averaging),
AI_PGAGAIN = 38.4×
0.3 %
Over a dynamic range of 3000 to 1, 1 sec (averaging),
AI_PGAGAIN = 16×, BI_PGAGAIN = 1×
0.6 %
Over a dynamic range of 3000 to 1, 1 sec (averaging),
AI_PGAGAIN = 38.4×
RMS Voltage (V
RMS
) 0.2 % Over a dynamic range of 1000 to 1, 1 sec (averaging)
Active Power (WATT), Fundamental
Reactive Power (VAR)
0.25 %
Over a dynamic range of 3000 to 1, 1 sec, AI_PGAGAIN =
16×
0.5 %
Over a dynamic range of 3000 to 1, 1 sec, AI_PGAGAIN =
38.4×
One Cycle RMS Current and Voltage
Refreshed Each Half Cycle
0.5 %
Over a dynamic range of 500 to 1 on current and 250 to
1 on voltage
1 %
Over a dynamic range of 1000 to 1 on current and 500 to
1 on voltage
Line Period Measurement 0.001 Hz Resolution at 50 Hz
Voltage to Current Angle
Measurement
0.036 Degrees Resolution at 50 Hz

ADE9153AACPZ

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Data Acquisition ADCs/DACs - Specialized 1 PH Mtr IC w/ Auto Calibration
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union