NXP Semiconductors
NHS3152
Therapy adherence resistive monitor
NHS3152 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
Product data sheet Rev. 3.03 — 15 June 2018
8 / 51
Pad Symbol Type Description
17 AN0_5 A to AN0_BUS5
Radio
20 LA A NFC antenna/coil terminal A
19 LB A NFC antenna/coil terminal B
Reset
9 RESETN I external reset input
[5]
[1] The GPIO port is a 12-bit I/O port with individual direction and function controls for each bit. The operation of port 0 pads
depends on the function selected through the IOCONFIG register block.
[2] If external wake-up is enabled on this pad, it must be pulled HIGH before entering Deep power-down mode and pulled
LOW for a minimum of 100 μs to exit Deep power-down mode.
[3] Open drain, no pull-up or pull down.
[4] The analog port is a 6-input analog I/O port with enable control for each pad.
[5] A LOW on this pin resets the device. This reset causes I/O ports and peripherals to take on their default states, and
processor execution to begin at address 0. It has weak pull-up to V
BAT
or internal NFC voltage (whichever is highest).
7.1.2 WLCSP25 package
Figure 3 shows the ball layout of the NHS3152 in the WLCSP25 package.
A
B
C
D
E
ball A1
index area
NHS31xx
aaa-024232
Transparent top view
1 2 3 4 5
Figure 3. Ball configuration WLCSP25
Table 5. Ball allocation table of the WLCSP25 package
Ball Symbol Ball Symbol
A1 VDDBAT C4
[1]
PIO0_7/CT16B_M1
A2 VSS C5
[1]
PIO0_11/CT32B_M1/SWDIO
A3 RESETN D1 PIO0_0/WAKEUP
A4 PIO0_4/SCL D2 PIO0_1/CLKOUT
A5 PIO0_5/SDA D3 AN0_2
B1 PIO0_8/MISO D4 AN0_4
B2 PIO0_9/MOSI D5 AN0_5