LTC3676/LTC3676-1
28
3676fe
For more information www.linear.com/LTC3676
OPERATION
Figure 15. LTC3676 I
2
C Serial Port Multiple Write Pattern
Figure 16. LTC3676 I
2
C Serial Port Read Pattern
1 2 3 4 5 6 7 8
0
0
1 1 1 1
1 1 1 1
ADDRESS
0 0
0 0
0
W
9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
ACK
3676 F15
ACKACKACKACK
START
SDA
SCL
STOP
S7 S6 S5 S4 S3
SUB ADDRESS
S2 S1
S0
D7 D6 D5 D4 D3
DATA
D2 D1
D0
S7 S6 S5 S4 S3
SUB ADDRESS
S2 S1
S0
D7 D6 D5 D4 D3
DATA
D2 D1
D0
0
START
SDA
SCL
1 1 1
1 2 3 4 5 6 7 8
10 1 1 1 0 0 0
9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8
10011110
START
9 1 2 3 4 5 6 7 8 9
3676 F16
ACKACKACKACK
STOP
1
ADDRESS
0 0
W
S7 S6 S5 S4 S3
SUB ADDRESS
S2 S1
S0
0 1 1 1 1
ADDRESS
0 0
R
R7 R6 R5 R4 R3
DATA
R2 R1
R0
LTC3676/LTC3676-1
29
3676fe
For more information www.linear.com/LTC3676
OPERATION
REG NAME B[7] B[6] B[5] B[4] B[3] B[2] B[1] B[0] DEFAULT
0x01 BUCK1 Enable:
0 = Disabled if
EN_B1 Low
1 = Enabled
Mode:
00 = Pulse-Skipping
01 = Burst
10 = Forced Continuous
Start-Up:
0 =
Enable at
Any
Output
Voltage
1 = Enable
Only if Output
<300mV
Phase Select:
0 = Clock
Phase 1
1 = Clock
Phase 2
Clock Rate:
0 = 2.25MHz
1 = 1.125MHz
Keep
Alive
Buck1:
0 = Do Not
Keep Alive
1= Keep Alive in
Shutdown.
Switch DV/DT
Control:
0 = Slow
1 = Fast
0000 0000
0x02
BUCK2 Enable:
0 = Disabled if
EN_B2
Low
1 = Enabled
Mode:
00 = Pulse-Skipping
01 = Burst
10 = Forced Continuous
Start-Up:
0 =
Enable at
Any
Output
Voltage
1 = Enable
Only if Output
<300mV
Phase Select:
0 = Clock
Phase 1
1 = Clock
Phase 2
Clock Rate:
0 = 2.25MHz
1 = 1.125MHz
Keep
Alive
Buck2:
0 = Do Not
Keep Alive
1 = Keep Alive
in Shutdown
Switch DV/DT
Control:
0 = Slow
1 = Fast
0000 0000
0x03
BUCK3 Enable:
0 = Disabled if
EN_B3
Low
1 = Enabled
Mode:
00 = Pulse-Skipping
01 = Burst
10 = Forced Continuous
Start-Up:
0 =
Enable at
Any
Output
Voltage
1 = Enable
Only if Output
<300mV
Phase Select:
0 = Clock
Phase 1
1 = Clock
Phase 2
Clock Rate:
0 = 2.25MHz
1 = 1.125MHz
Keep
Alive
Buck3:
0 = Do Not
Keep Alive
1 = Keep Alive
in Shutdown
Switch DV/DT
Control:
0 = Slow
1 = Fast
0000 0000
0x04
BUCK4 Enable:
0 = Disabled if
EN_B4
Low
1 = Enabled
Mode:
00 = Pulse-Skipping
01 = Burst
10 = Forced Continuous
Start-Up:
0 =
Enable at
Any
Output
Voltage
1 = Enable
Only if Output
<300mV
Phase Select:
0 = Clock
Phase 1
1 = Clock
Phase 2
Clock Rate:
0 = 2.25MHz
1 = 1.125MHz
Keep
Alive
Buck4:
0 = Do Not
Keep Alive
1 = Keep Alive
in Shutdown
Switch DV/DT
Control:
0 = Slow
1 = Fast
0000 0000
0x05
LDOA Reserved Reserved Enable LDO3:
0 = Disabled if
EN_L3
Low
1 = Enabled
Start-Up LDO3:
0 = Enable at
Any Output
Voltage
1 = Enable
Only if Output
<300mV
Keep Alive
LDO3:
0 = Do Not
Keep
Alive
1 = Keep Alive
in Shutdown.
Enable LDO2:
0 = Disabled if
EN_L2
Low
1 = Enabled
Start-Up LDO2:
0 = Enable at
Any Output
Voltage
1 = Enable
Only if Output
<300mV
Keep Alive
LDO2:
0 = Do Not
Keep
Alive
1 = Keep Alive
in Shutdown
XX00 0000
0x06 LDOB Reserved Reserved Reserved LTC3676-1 LDO4 Output
Voltage:
00 = 1.2V
01 = 2.5V
10 = 2.8V
11 = 3.0V
Enable
LDO4:
0 = Disabled if
EN_L4
Low
1 = Enabled
Start-Up LDO4:
0 = Enable at
Any Output
Voltage
1 = Enable
Only if Output
<300mV
Keep Alive
LDO4:
0 = Do Not
Keep
Alive
1 = Keep Alive
in Shutdown
XX00 0000
0x07 SQD1 Sequence Down Buck4:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
Sequence
Down Buck3:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
Sequence
Down Buck2:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
Sequence
Down Buck1:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
0000 0000
Table 20. LTC3676 Command Registers
LTC3676/LTC3676-1
30
3676fe
For more information www.linear.com/LTC3676
OPERATION
REG NAME B[7] B[6] B[5] B[4] B[3] B[2] B[1] B[0] DEFAULT
0x08 SQD2 Reserved Reserved Sequence Down LD04:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
Sequence
Down LD03:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
Sequence
Down LD02:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
XX00 0000
0x09
CNTRL PWR_ON:
0 = Not
PWR_ON
1 =
PWR_ON
"ORed" with
PWR_ON PIN
Pushbutton
Hard Reset
Timer:
0 = 10 sec
1 = 5 sec
Software
Control
Mode:
0 = Pin or
Register
Control
1 =
Inhibit Pin
Control
UV Warning Threshold:
000 = 2.7V
001 = 2.8V
010 = 2.9V
011 = 3.0V
100 = 3.1V
101 = 3.2V
110 = 3.3V
111 = 3.4V
Over
temperature Warning
Levels:
00 = 10°C Below
Overtemperature
01 = 20°
C Below
Overtemperature
10 = 30°C Below
Overtemperature
11 = 40°C Below
Overtemperature
0000 0000
0x0A DVB1A Reserved Reserved Buck1
Reference
Select:
0 =
DVB1A[4-0]
1 =
DVB1B[4-0]
Buck1
Feedback Reference Input (VA):
00000 = 412.5mV
11001 = 725mV
11111 = 800mV
12.5mV Step
Size
XX01 1001
0x0B DVB1B Reserved Reserved PGOOD Mask:
0 = PGOOD
Low
When
Slewing
1 = PGOOD
Not Forced
Low When
Slewing
Buck1 Feedback Reference Input (VB):
00000 = 412.5mV
11001 = 725mV
11111 = 800mV
12.5mV Step
Size
XX01 1001
0x0C DVB2A Reserved Reserved Buck2
Reference
Select:
0 =
DVB2A[4-0]
1 =
DVB2B[4-0]
Buck2
Feedback Reference Input (VA):
00000 = 412.5mV
11001 = 725mV
11111 = 800mV
12.5mV Step Size
XX01 1001
0x0D
DVB2B Reserved Reserved PGOOD Mask:
0 = PGOOD
Low
When
Slewing
1 = PGOOD
Not Forced
Low When
Slewing
Buck2 Feedback Reference Input (VB):
00000 = 412.5mV
11001 = 725mV
11111 = 800mV
12.5mV Step
Size
XX01 1001
0x0E DVB3A Reserved Reserved Buck3
Reference
Select:
0 =
DVB3A[4-0]
1 =
DVB3B[4-0]
Buck3
Feedback Reference Input (VA):
00000 = 412.5mV
11001 = 725mV
11111 = 800mV
12.5mV Step
Size
XX01 1001