XR16L2552
13
REV. 1.1.2 2.25V TO 5.5V DUART WITH 16-BYTE FIFO
2.13 Receiver
The receiver section contains an 8-bit Receive Shift Register (RSR) and 16 bytes of FIFO which includes a
byte-wide Receive Holding Register (RHR). The RSR uses the 16X for timing. It verifies and validates every bit
on the incoming character in the middle of each data bit. On the falling edge of a start or false start bit, an
internal receiver counter starts counting at the 16X. After 8 clocks the start bit period should be at the center of
the start bit. At this time the start bit is sampled and if it is still a logic 0 it is validated. Evaluating the start bit in
this manner prevents the receiver from assembling a false character. The rest of the data bits and stop bits are
sampled and validated in this same manner to prevent false framing. If there were any error(s), they are
reported in the LSR register bits 2-4. Upon unloading the receive data byte from RHR, the receive FIFO pointer
is bumped and the error tags are immediately updated to reflect the status of the data byte in RHR register.
RHR can generate a receive data ready interrupt upon receiving a character or delay until it reaches the FIFO
trigger level. Furthermore, data delivery to the host is guaranteed by a receive data ready time-out interrupt
when data is not received for 4 word lengths as defined by LCR[1:0] plus 12 bits time. This is equivalent to 3.7-
4.6 character times. The RHR interrupt is enabled by IER bit-0.
2.13.1 Receive Holding Register (RHR) - Read-Only
The Receive Holding Register is an 8-bit register that holds a receive data byte from the Receive Shift
Register. It provides the receive data interface to the host processor. The RHR register is part of the receive
FIFO of 16 bytes by 11-bits wide, the 3 extra bits are for the 3 error tags to be reported in LSR register. When
the FIFO is enabled by FCR bit-0, the RHR contains the first data character received by the FIFO. After the
RHR is read, the next character byte is loaded into the RHR and the errors associated with the current data
byte are immediately updated in the LSR bits 2-4
F
IGURE 8. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE
Transmit Data Shift Register
(TSR)
Transmit
Data Byte
THR Interrupt (ISR bit-1) falls
below the programmed Trigger
Level and then when becomes
empty. FIFO is Enabled by FCR
bit-0=1
Transmit
FIFO
16X Clock
Auto CTS Flow Control (CTS# pin)
Auto Software Flow Control
Flow Control Characters
(Xoff1/2 and Xon1/2 Reg.
TXFIFO1
XR16L2552
14
2.25V TO 5.5V DUART WITH 16-BYTE FIFO REV. 1.1.2
.
F
IGURE 9. RECEIVER OPERATION IN NON-FIFO MODE
FIGURE 10. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE
Receive Data Shift
Register (RSR)
Receive
Data Byte
and Errors
RHR Interrupt (ISR bit-2)
Receive Data
Holding Register
(RHR)
RXFIFO1
16X Clock
Receive Data Characters
Data Bit
Validation
Error
Tags in
LSR bits
4:2
Receive Data Shift
Register (RSR)
RXFIFO1
16X Clock
Error Tags
(16-sets)
Error Tags in
LSR bits 4:2
16 bytes by 11-bit
wide
FIFO
Receive Data Characters
FIFO Trigger=8
Example
:
- RX FIFO trigger level selected at 8 bytes
Data fills to 14
Data falls to 4
Data Bit
Validation
Receive
Data FIFO
Receive
Data
Receive Data
Byte and Errors
RHR Interrupt (ISR bit-2) programmed for
desired FIFO trigger level.
FIFO is Enabled by FCR bit-0=1
RTS# de-asserts when data fills above the flow
control trigger level to suspend remote transmitter.
Enable by EFR bit-6=1, MCR bit-2.
RTS# re-asserts when data falls below the flow
control trigger level to restart remote transmitter.
Enable by EFR bit-6=1, MCR bit-2.
XR16L2552
15
REV. 1.1.2 2.25V TO 5.5V DUART WITH 16-BYTE FIFO
2.14 Auto RTS (Hardware) Flow Control
Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS#
output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control
features is enabled to fit specific application requirement (see Figure 11):
Enable auto RTS flow control using EFR bit-6.
The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled).
If using the Auto RTS interrupt:
Enable RTS interrupt through IER bit-6 (after setting EFR bit-4). The UART issues an interrupt when the
RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1.
2.15 Auto CTS Flow Control
Automatic CTS flow control is used to prevent data overrun to the remote receiver FIFO. The CTS# input is
monitored to suspend/restart the local transmitter. The auto CTS flow control feature is selected to fit specific
application requirement (see Figure 11):
Enable auto CTS flow control using EFR bit-7.
If using the Auto CTS interrupt:
Enable CTS interrupt through IER bit-7 (after setting EFR bit-4). The UART issues an interrupt when the CTS#
pin is de-asserted (HIGH): ISR bit-5 will be set to 1, and UART will suspend transmission as soon as the stop
bit of the character in process is shifted out. Transmission is resumed after the CTS# input is re-asserted
(LOW), indicating more data may be sent.