SL2S2002_SL2S2102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 3.4 — 10 August 2017
COMPANY PUBLIC 178034 13 / 39
9.3 Communication principle
For detailed description of the protocol and timing please refer to ISO/IEC 15693-2
(modulation, bit-coding, framing, Ref. 2) and ISO/IEC 15693-3 (anticollision, timing,
protocol, Ref. 3).
9.4 Supported commands
9.4.1 Mandatory commands
9.4.1.1 INVENTORY
As defined in ISO/IEC 15693-3.
9.4.1.2 STAY QUIET
As defined in ISO/IEC 15693-3.
9.4.2 Optional commands
9.4.2.1 READ SINGLE BLOCK
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
9.4.2.2 WRITE SINGLE BLOCK
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
9.4.2.3 LOCK BLOCK
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
9.4.2.4 READ MULTIPLE BLOCKS
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
NXP Semiconductors
SL2S2002_SL2S2102
ICODE SLIX
SL2S2002_SL2S2102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 3.4 — 10 August 2017
COMPANY PUBLIC 178034 14 / 39
Remark: If the sum of the first block number and the number of blocks exceeds the
total available number of user blocks, the number of transmitted blocks is less than the
requested number of blocks, which means that the last returned block is the highest
available user block, followed by the 16-bit CRC and the EOF.
9.4.2.5 SELECT
As defined in ISO/IEC 15693-3.
9.4.2.6 RESET TO READY
As defined in ISO/IEC 15693-3.
9.4.2.7 WRITE AFI
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
Remark: This command maybe password protected, refer to Section 9.4.3.11
"PASSWORD PROTECT EAS/AFI".
9.4.2.8 LOCK AFI
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
Remark: This command maybe password protected, refer to Section 9.4.3.11
"PASSWORD PROTECT EAS/AFI".
9.4.2.9 WRITE DSFID
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
9.4.2.10 LOCK DSFID
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
9.4.2.11 GET SYSTEM INFORMATION
As defined in ISO/IEC 15693-3.
The TAG type of the ICODE SLIX is "01h".
NXP Semiconductors
SL2S2002_SL2S2102
ICODE SLIX
SL2S2002_SL2S2102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 3.4 — 10 August 2017
COMPANY PUBLIC 178034 15 / 39
9.4.2.12 GET MULTIPLE BLOCK SECURITY STATUS
As defined in ISO/IEC 15693-3.
Remark: If the sum of the first block number and the number of blocks exceeds the total
available number of user blocks the number of transmitted security status bytes is less
than the requested number, which means that the last returned status byte is the one
corresponding to the highest available user block, followed by the 16-bit CRC and the
EOF.
9.4.3 Custom commands
The manufacturer code of NXP Semiconductors is defined in ISO/IEC 7816-6A1 (Ref. 5).
It has the value "04h".
For the structure of custom commands please refer to ISO/IEC 15693-3.
If not explicitly specified differently all address modes are supported.
9.4.3.1 GET RANDOM NUMBER
Command code = B2h
The GET RANDOM NUMBER command is required to receive a random number from
the label IC. The passwords that will be transmitted with the SET PASSWORD command
have to be calculated with the password and the random number (see Section 9.4.3.2
"SET PASSWORD").
The different passwords are addressed with the password identifier.
Table 8. Request format
SOF Flags GET
RANDOM
NUMBER
IC Mfg
code
UID CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
16 bits -
Table 9. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 10. Response format when Error_flag NOT set
SOF Flags Random
number
CRC16 EOF
- 8 bits 16 bits 16 bits -
9.4.3.2 SET PASSWORD
Command code = B3h

SL2S2102FUD,003