The SET PASSWORD command enables the EAS/AFI password to be transmitted to the
label to access EAS and/or AFI (if the EAS and/or AFI password is enabled). The SET
PASSWORD command has to be executed just once for the related password if the label
is powered.
Remark: The SET PASSWORD command can only be executed in Addressed or
Selected mode.
The XOR password has to be calculated with the password and two times the received
random number from the last GET RANDOM NUMBER command:
XOR_Password[31:0] = Password[31:0] XOR {Random_Number[15:0],
Random_Number[15:0]}.
The EAS/AFI password is addressed with the password identifier.
Table 11. Request format
SOF Flags SET
PASSWORD
IC Mfg
code
UID Password
identifier
XOR
password
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 32 bits 16 bits -
Table 12. Password Identifier
Password identifier Password
10h EAS/AFI
Table 13. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 14. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
Remark: If the IC receives an invalid password, it will not execute any following
command until a Power-On Reset (POR) (RF reset) is executed.
9.4.3.3 WRITE PASSWORD
Command code = B4h
The WRITE PASSWORD command enables a new password to be written into the
related memory if the related old password has already been transmitted with a SET
PASSWORD command and the addressed password is not locked (see Section 9.4.3.4
"LOCK PASSWORD").
Remark: The WRITE PASSWORD command can only be executed in addressed
or selected mode. The new password takes effect immediately which means that the
NXP Semiconductors
SL2S2002_SL2S2102
ICODE SLIX
SL2S2002_SL2S2102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 3.4 — 10 August 2017
COMPANY PUBLIC 178034 17 / 39
new password has to be transmitted with the SET PASSWORD command to access
protected blocks.
The EAS/AFI password is addressed with the password identifier.
The timing of the command is write alike.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
Table 15. Request format
SOF Flags WRITE
PASSWORD
IC Mfg
code
UID Password
identifier
Password CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 32 bits 16 bits -
Table 16. Password identifier
Password identifier Password
10h EAS/AFI
Table 17. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 18. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
9.4.3.4 LOCK PASSWORD
Command code = B5h
The LOCK PASSWORD command enables the addressed password to be locked if the
related password has already been transmitted with a SET PASSWORD command. A
locked password cannot be changed.
The EAS/AFI password is addressed with the password identifier.
The timing of the command is write alike.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
NXP Semiconductors
SL2S2002_SL2S2102
ICODE SLIX
SL2S2002_SL2S2102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 3.4 — 10 August 2017
COMPANY PUBLIC 178034 18 / 39
Table 19. Request format
SOF Flags LOCK
PASSWORD
IC Mfg
code
UID Password
identifier
CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
8 bits 16 bits -
Table 20. Password identifier
Password identifier Password
10h EAS/AFI
Table 21. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 22. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
9.4.3.5 INVENTORY READ
Command code = A0h
When receiving the INVENTORY READ request, the ICODE SLIX IC performs the same
as the anticollision sequence, with the difference that instead of the UID and the DSFID,
the requested memory content is re-transmitted from the ICODE SLIX IC.
If an error is detected, the ICODE SLIX IC remains silent.
If the Option flag is set to logic 0, n blocks of data are re-transmitted. If the Option flag
is set to 1, n blocks of data and the part of the UID which is not part of the mask are re-
transmitted.
The request contains:
Flags
INVENTORY READ command code
IC manufacturer code
AFI (if AFI flag set)
Mask length
Mask value (if mask length > 0)
First block number to be read
Number of blocks to be read
CRC 16