NXP Semiconductors
SL2S2002_SL2S2102
ICODE SLIX
SL2S2002_SL2S2102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 3.4 — 10 August 2017
COMPANY PUBLIC 178034 22 / 39
Table 34. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 35. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
9.4.3.10 EAS ALARM
Command code = A5h
If the EAS mode is enabled, the EAS sequence is returned from the ICODE SLIX IC.
Table 36. Request format
SOF Flags EAS
ALARM
IC Mfg code UID CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits
optional
16 bits -
If an error is detected the ICODE SLIX IC remains silent.
Table 37. Response format
SOF Flags EAS sequence CRC16 EOF
- 8 bits 256 bits 16 bits -
EAS sequence (starting with the LSB, which is transmitted first; read from left to right):
11110100 11001101 01000110 00001110 10101011 11100101 00001001 11111110
00010111 10001101 00000001 00011100 01001011 10000001 10010010 01101110
01000001 01011011 01011001 01100001 11110110 11110101 11010001 00001101
10001111 00111001 10001011 01001000 10100101 01001110 11101100 11110111
If the EAS mode is disabled the ICODE SLIX IC remains silent.
9.4.3.11 PASSWORD PROTECT EAS/AFI
Command code = A6h
The PASSWORD PROTECT EAS/AFI command enables the password protection for
EAS and/or AFI if the EAS/AFI password is first transmitted with the SET PASSWORD
command.
Option flag set to logic 0: EAS will be password protected.
Option flag set to logic 1: AFI will be password protected.
Both password protections (AFI and EAS) can be enabled separately.
Remark: Independent of the Option flag, this write-alike command will be executed like a
write command with Option flag 0 (Option flag not set).
Once the EAS/AFI password protection is enabled, it is not possible to change back to
unprotected EAS and/or AFI.
NXP Semiconductors
SL2S2002_SL2S2102
ICODE SLIX
SL2S2002_SL2S2102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 3.4 — 10 August 2017
COMPANY PUBLIC 178034 23 / 39
The timing of the command is write alike (as write command with Option flag 0).
Table 38. Request format
SOF Flags PASSWORD
PROTECT EAS/
AFI
IC Mfg code UID CRC16 EOF
- 8 bits 8 bits 8 bits 64 bits optional 16 bits -
Table 39. Response format when Error_flag set
SOF Flags Error code CRC16 EOF
- 8 bits 8 bits 16 bits -
Table 40. Response format when Error_flag NOT set
SOF Flags CRC16 EOF
- 8 bits 16 bits -
9.5 Error handling
9.5.1 Transmission errors
According to ISO/IEC 15693 the label IC will not respond if a transmission error (CRC,
bit coding, bit count, wrong framing) is detected and will silently wait for the next correct
received command.
9.5.2 Not supported commands or options
If the received command or option is not supported, the behavior of the label IC depends
on the addressing mechanism.
9.5.2.1 Non Addressed Mode
The label IC remains silent.
9.5.2.2 Addressed or Selected Mode
The addressed or selected label IC responds with the error code "0Fh" (error with no
information given or error code is not supported).
If the Inventory flag or the Protocol Extension flag is set, the label IC will not respond if
the command or option is not supported.
NXP Semiconductors
SL2S2002_SL2S2102
ICODE SLIX
SL2S2002_SL2S2102 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2017. All rights reserved.
Product data sheet Rev. 3.4 — 10 August 2017
COMPANY PUBLIC 178034 24 / 39
9.5.3 Parameter out of range
9.5.3.1 Read commands
If the sum of the first block number and the number of blocks exceeds the total available
number of user blocks, the number of transmitted blocks is less than the requested
number of blocks, which means that the last returned block is the highest available user
block, followed by the 16-bit CRC and the EOF.
9.5.3.2 Write and lock commands
If the address of a block to be written does not exist or a block to be written is locked, the
behaviour of the label IC depends on the addressing mechanism.
Non Addressed Mode
The label IC remains silent and aborts the command without writing anything.
Addressed or Selected Mode
The addressed or selected label IC responds with the error code "0Fh"(error with no
information given or error code is not supported).
9.6 Data integrity
Following mechanisms are implemented in the contactless communication link between
interrogator and label to ensure very reliable data transmission:
16-bit CRC per block
Bit count checking
Bit coding to distinguish between logic 1, logic 0, and no information
Channel monitoring (protocol sequence and bit stream analysis)
9.7 RF interface
The definition of the RF interface is according to the standard ISO/IEC 15693-2 and ISO/
IEC 15693-3.

SL2S2102FUD,003

Mfr. #:
Manufacturer:
NXP Semiconductors
Description:
RFID Transponders ICODE SLIX
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union