DC and AC parameters M95160-x, M95080-x
26/49 Doc ID 8028 Rev 11
9 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 9. Operating conditions (M95160 and M95080)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 4.5 5.5 V
T
A
Ambient operating temperature (device grade 6) –40 85 °C
Ambient operating temperature (device grade 3) –40 125 °C
Table 10. Operating conditions (M95160-W and M95080-W)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature (device grade 6) –40 85 °C
Ambient operating temperature (device grade 3) –40 125 °C
Table 11. Operating conditions (M95160-R and M95080-R)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 12. Operating conditions (M95160-F)
(1)
1. Preliminary data.
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 13. AC measurement conditions
(1)
1. Output Hi-Z is defined as the point where data out is no longer driven.
Symbol Parameter Min. Typ. Max. Unit
C
L
Load capacitance 30 pF
Input rise and fall times 50 ns
Input pulse voltages 0.2V
CC
to 0.8V
CC
V
Input and output timing reference voltages 0.3V
CC
to 0.7V
CC
V