DC and AC parameters M95160-x, M95080-x
28/49 Doc ID 8028 Rev 11
Table 16. DC characteristics (M95160 and M95080, device grade 6)
Symbol Parameter Test conditions Min. Max. Unit
I
LI
Input leakage current V
IN
= V
SS
or
V
CC
± 2 µA
I
LO
Output leakage current S = V
CC
, V
OUT
= V
SS
or
V
CC
± 2 µA
I
CC
Supply current
C = 0.1V
CC
/0.9V
CC
at 10 MHz,
V
CC
= 5 V, Q = open
5mA
I
CC1
Supply current
(Standby)
S = V
CC
, V
CC
= 5 V,
V
IN
= V
SS
or
V
CC
2µA
V
IL
Input low voltage –0.45 0.3 V
CC
V
V
IH
Input high voltage 0.7 V
CC
V
CC
+1 V
V
OL
(1)
1. For all 5 V range devices, the device meets the output requirements for both TTL and CMOS standards.
Output low voltage I
OL
= 2 mA, V
CC
= 5 V 0.4 V
V
OH
(1)
Output high voltage I
OH
= –2 mA, V
CC
= 5 V 0.8 V
CC
V
V
RES
(2)
2. Characterized only, not 100% tested.
Internal reset threshold
voltage
2.5 3.5 V
Table 17. DC characteristics (M95160-W and M95080-W, device grade 3)
Symbol Parameter Test conditions Min. Max. Unit
I
LI
Input leakage
current
V
IN
= V
SS
or
V
CC
± 2 µA
I
LO
Output leakage
current
S
= V
CC
, V
OUT
= V
SS
or
V
CC
± 2 µA
I
CC
Supply current
C=0.1V
CC
/0.9V
CC
at 5 MHz,
V
CC
= 2.5 V, Q = open
2mA
I
CC1
Supply current
(Standby)
S
= V
CC
, V
CC
= 2.5 V, V
IN
= V
SS
or
V
CC
2µA
V
IL
Input low voltage –0.45 0.3 V
CC
V
V
IH
Input high voltage 0.7 V
CC
V
CC
+1 V
V
OL
Output low voltage I
OL
= 1.5 mA, V
CC
= 2.5 V 0.4 V
V
OH
Output high voltage I
OH
= –0.4 mA, V
CC
= 2.5 V 0.8 V
CC
V
V
RES
(1)
1. Characterized only, not 100% tested.
Internal reset
threshold voltage
1.0 1.65 V